4-3-18 Other

1. Current sensor error
Check PCB operates normally then replace the PCB
2. Compressor V limit error
Check the compressor operates normally then replace the compressor. If an error still occurs after the replacement of the
compressor, replace the PCB
3. OTP error
Check PCB operates normally then replace the PCB
4. DC link Voltage Sensor Error
Check the connection between input power and the power is okay then replace the PCB
5. AC zero Crossing signal out error
Check the connection between input power and the power is okay then replace the PCB
6. Inconsistent volume
Check the option code of the indoor unit.