Now turn the knob (3) fully in the opposite direction, as far as the
position with the "big flame". You can now adjust the height of the
6
7
8
Figure 13: Ultrasound remote control
If this starts "ticking", you have reached the highest or lowest
position. The flames can also be adjusted to the desired size manually
with the right-hand control knob (4).
3.2.2

Extinguishing the burners

The burners can be extinguished as follows: turn the ignition knob (3)
a quarter turn to the left as far as the "pilot light" position. The
burners will now be extinguished, however the pilot light will stay
alight. The burners can be re-ignited by turning the knob back to the
position with the "flames".
If you do not wish to use the appliance over an extended period of
time, you can turn the knob (3) all the way back to the symbol " ",
which will also extinguish the pilot light, at the same time you can
also turn off the gas tap.
flames
with
the
remote
control
(Figure
13).
For
higher flames, press
in the top knob (6)
and
the
left-hand
knob
(8)
simultaneously.
For
lower flames, press in
the bottom knob (7).
The remote control is
ultrasound,
so
you
have
to
point
the
remote control in the
right direction.
soon as the receiver
reacts, you will hear a
small motor running.
33
3.3

Appliances with radio remote control

Take the battery-protection strip out of the manual transmitter and
check that the battery is still correctly positioned between the two
contacts. Plug into the electric socket and turn on the gas tap.
3.3.1

Lighting the burners

When the Big flame (Figure 14 no. 1) and the "Off" knob (no. 3) are
pushed in simultaneously (two-knob ignition!!), after a few seconds
the ignition will automatically start sparking. When the pipe and the
gas control unit are filled with gas, a pilot light will appear and the
1
2
As
3
Figure 14 resetting
burners will start with a large flame and are then continuously
adjustable between maximum and minimum. You can adjust the
burners higher and lower with no. 1 and no. 2.
Resetting the appliance
If still no flame is detected after 30 seconds of
sparking, the automated burner unit safety-lock
will be activated. You can reset the automatic
burner unit by means of the remote control and/or
a reset knob on the automatic burner unit itself.
(This procedure may have to be repeated several
times when the appliance is first used or if it has
been out of use for an extended period).
I
On the remote control you then press in the
"small flame" and "X" simultaneously (1) and
then immediately press "X" (2) again. (see
Figure 15).
sparking will stop. If the sparking
does NOT stop, there can only be
two reasons for this: the gas supply
is still closed off (no pilot light can
be seen); in this case turn on the
gas tap - or the plug is not pushed
into the electric socket correctly
(there is a pilot light, but the
ignition keeps on sparking), then
the plug has to be turned round in
the electric socket (NL) or the L and
N wires need to be swapped over in
the black receiver box (BE). When
the pilot light is burning, the main
2
Figure 15 resetting
34