Mitsubishi Heavy Industries SRK20ZG-S Tech Manual page 60

Inverter wall mounted type room air-conditioner ( split system, air to air heat pump type )
Hide thumbs Also See for SRK20ZG-S:
Table of Contents

Advertisement

Super link adapter connection
See the super link adapter's manual concerning connections to the super link adapter.
1Cut jumper wire (J2) on the circuit board.
Caution: This device cannot be used together with the wireless remote
control which is supplied with the indoor unit.
2Connections between the interface and super link adapter
Z
Interface side
Y
Super link
adapter
X
terminal block
3Fasten the super link adapter cable with clamps.
CNT connector functions
Turning the contacts ON/OFF, the off/running status of the air conditioner can be monitored from the External control unit (remote display).
1Connect a locally procured remote control
unit to the CNT terminal.
2In case of the pulse input, cut off the
jumper wire "J1" on the main unit PCB.
3When setting at Operation
permission/prohibition Mode, cut off the
jumper wire "J3".
Input
Output
Output 1
Operation output
ON output (X
Output 2
Heating output
ON output (X
Compressor
Output 3
ON output (X
operation output
Output 4
Malfunction output
ON output (X
Level input
(At shipment)
Level input
(At shipment)
Remote
Input
control input
Pulse input
(J1 cut)
Pulse input
(J1 cut)
In the operation permited/prohibited mode, remote control operations are allowed only when the input is turned ON.
Z terminal: black wire
Z
Y terminal: white wire
Super link
Y
adapter
X terminal: red wire
X
1
2
3
4
5
CNT connector
6
Content
= ON) during air conditioner operation
R1
= ON) during heating operation
R2
= ON) during compressor operation
R3
= ON) during an abnormal stop
R4
External control
X
OFF
R5
(At shipment)
X
ON
R5
Operation permission
X
OFF
R5
/prohibition (J3 cut)
X
ON
R5
External control
X
Air conditioner ON/OFF is inverted
R5
(At shipment)
depending on the pulse signal at OFF
Operation permission
X
Air conditioner ON/OFF is inverted
R5
/prohibition (J3 cut)
depending on the pulse signal at OFF
No.
Shielded wire
1
Vinyl cabtyre round cord
2
Vinyl cabtyre round cable
3
Vinyl insulated wirevinyl sheathed cable for control
4
Within 200 m 0.5 mm
Within 300 m 0.75 mm
Within 400 m 1.25 mm
Within 600 m 2.0 mm
0.3 mm
(Keep the distance between the relay and the CNT terminal within 2 m.)
2
X
R1
X
R2
X
R3
X
R4
X
R5
ON
Air conditioner ON
OFF
Air conditioner OFF
ON
Air conditioner OFF
OFF
Air conditioner OFF
ON.
ON.
57
-
-
Jumper wire (J2)
Names of recommended signal wires
× 3 cores
2
× 3 cores
2
× 3 cores
2
× 3 cores
2
Common
Output 1
X
R1
Output 2
X
R2
Output 3
X
R3
Output 4
X
R4
X
Input
R5
X
are for the DC 12V relay
R1~4
X
is a DC 12/24 or AC 220~240V relay
R5
CNT connector (local) maker, model
Connector
Molex
Terminals
Molex
Power supply
DC 12/24 V
or
AC 220~240V
5264-06
5263T
Jumper wire (J3)
Jumper wire (J1)