Temperature Setting - Mitsubishi Heavy Industries SRK20ZG-S Tech Manual

Inverter wall mounted type room air-conditioner ( split system, air to air heat pump type )
Hide thumbs Also See for SRK20ZG-S:
Table of Contents

Advertisement

2 Stop data
Remote control setting
Operation
switching
Cooling
(c) Error code, stop code table (Assignment of error codes and stop codes is done in common for all models.)
Number of flashes
when in service mode
Stop code
or
RUN
TIMER
Error code
light
light
(10's digit)
(1's digit)
Major category
OFF
OFF
0
Normal
11
Current
1 time
1 time
flash
flash
2 time
12
flash
13
3 time
flash
4 time
14
flash
5 time
15
flash
6 time
16
flash
21
2 time
1 time
Outdoor
flash
flash
2 time
22
flash
23
3 time
flash
9 time
29
flash
7 time
27
Outdoor
flash
fan motor
3 time
1 time
31
Current
flash
flash
2 time
32
flash
3 time
33
flash
34
4 time
flash
5 time
35
flash
6 time
36
flash
7 time
37
flash
Temperature
Fan speed
switching
setting
LO
21°C
22°C
23°C
24°C
25°C
26°C
27°C
28°C
29°C
30°C
Error content
Minor category
-
-
Compressor Software Start Compressor lock
Cut
Compressor wiring short circuit
Compressor output is open phase
Outdoor unit's circuit board is faulty
Service valve closed
Lower than 20 rps
Compressor output is open phase.
Electronic expansion valve is faulty.
20 rps or higher
Service valve is closed.
Compressor output is open phase.
Compressor is faulty.
Electronic expansion valve is faulty.
Outdoor unit's circuit board is defective.
Excessive voltage
(DC 350 V)
Power supply is abnormal.
Short circuit in the power
Outdoor unit's circuit board is faulty.
transistor (high side)
Power transistor is damaged.
Current cut circuit
Outdoor unit's circuit board is faulty.
breakdown
Power transistor is damaged.
PWM calculation results
Compressor wiring is disconnected.
are abnormal.
Power transistor is damaged.
unit
error
Compressor wiring is disconnected.
Input is 2A or lower
Outdoor unit's circuit board is faulty.
(PWM 90% or higher)
Abnormal stop 3 times in
Service valve is closed.
20 minutes.
Compressor output is open phase.
Electronic expansion valve is faulty.
Refrigerant is insufficient.
Voltage drop
Power supply construction is defective.
Outdoor unit's circuit board is faulty.
Outdoor unit's fan motor
Outdoor fan motor is faulty.
Connector connections are poor.
is abnormal
Outdoor unit's circuit board is faulty.
error
Overcharge
Cooling current safe I
Compressor lock
safe
Overcharge
Heating current safe I
Compressor lock
Overcharge
Cooling current safe II
Compressor lock
Overcharge
Heating current safe II
Compressor lock
Overcharge
Cooling current safe III
Compressor lock
Overcharge
Heating current safe III
Compressor lock
Overcharge
Heating current safe
III + 3A
Compressor lock
Displays the reason for the stop (stop code) the previous time when the air conditioner was stopped by protective stop control.
Displays the reason for the stop (stop code) 2 times previous when the air conditioner was stopped by protective stop control.
Displays the reason for the stop (stop code) 3 times previous when the air conditioner was stopped by protective stop control.
Displays the reason for the stop (stop code) 4 times previous when the air conditioner was stopped by protective stop control.
Displays the reason for the stop (stop code) 5 times previous when the air conditioner was stopped by protective stop control.
Displays the reason for the stop (stop code) 6 times previous when the air conditioner was stopped by protective stop control.
Displays the reason for the stop (stop code) 7 times previous when the air conditioner was stopped by protective stop control.
Displays the reason for the stop (stop code) 8 times previous when the air conditioner was stopped by protective stop control.
Displays the reason for the stop (stop code) 9 times previous when the air conditioner was stopped by protective stop control.
Displays the reason for the stop (stop code) 10 times previous when the air conditioner was stopped by protective stop control.
Cause
-
Compressor start fails 42 times in succession and the
reason for the final failure is current cut.
After the compressor starts, it stops due to current cut at
less than 20 rps.
When operation is stopped by current cut at 20 rps or
higher.
When the DC voltage (DC 280 V) exceeds 350 V.
When it is judged that the power transistor was damaged
at the time the compressor started.
When it is judged that the power transistor was damaged
at the time the compressor started.
When PWM calculation results of 0% continue for 3
minutes or longer.
When PWM calculation results of 90% and an input current
lower than the set value continue for 3 minutes or longer.
When an abnormal stop occurs 3 times with automatic
recovery within 20 minutes after the outdoor unit's power
supply was turned on.
When the power supply voltage drops during operation.
When a fan speed of 75 rpm or lower continues for 30
seconds or longer.
When there is a current safe stop in current safe I mode
during cooling operation.
When there is a current safe stop in current safe I mode
during heating operation.
When there is a current safe stop in current safe II mode
during cooling operation.
When there is a current safe stop in current safe II mode
during heating operation.
When there is a current safe stop in current safe III mode
during cooling operation.
When there is a current safe stop in current safe III mode
during heating operation.
When there is a current safe stop in current safe III + 3A
mode during heating operation.
37
-
-
Displayed data
Occurrence conditions
Error
Auto
display
recovery
-
-
(2 times)
-
-
-
-
-
-
-
-
-
(3 times)
-
-
-
-
-
-
-