Mitsubishi Heavy Industries SRK20ZG-S Tech Manual page 44

Inverter wall mounted type room air-conditioner ( split system, air to air heat pump type )
Hide thumbs Also See for SRK20ZG-S:
Table of Contents

Advertisement

(f)
Discharge pipe temperature table
RUN light
(10's digit)
Buzzer sound
(minus)
Yes
(sounds for 0.1 second)
No
(does not sound)
* If no data are recorded (error code is normal), the display for each sensor becomes as shown below.
Sensor name
Discharge pipe sensor temperature
(Example) Discharge pipe temperature: "122ºC"
* In the case of discharge pipe data, multiply the reading value by 2. (Below, 61 x 2 = "122ºC")
ON
Buzzer sound
(minus)
OFF
ON
RUN light
(10's digit)
OFF
ON
TIMER light
(1's digit)
OFF
TIMER light
(1's digit)
3
2
1
0
0
1
2
3
4
5
6
7
Sensor value displayed when the error code is normal
0.1 sec.
If the temperature is < 0, the buzzer sounds.
If the temperature is > = 0, the buzzer does not sound.
1.5 sec.
0.5 sec.
0.5 sec.
41
-
0
1
2
3
-60
-62
-64
-40
-42
-44
-46
-20
-22
-24
-26
-2
-4
-6
0
2
4
6
20
22
24
26
40
42
44
46
60
62
64
66
80
82
84
86
100
102
104
106
120
122
124
126
140
142
144
146
-64 C
11-second interval
-
Units: C
4
5
6
7
8
-48
-50
-52
-54
-56
-28
-30
-32
-34
-36
-8
-10
-12
-14
-16
8
10
12
14
16
28
30
32
34
36
48
50
52
54
56
68
70
72
74
76
88
90
92
94
96
108
110
112
114
116
128
130
132
134
136
148
150
9
-58
-38
-18
18
38
58
78
98
118
138

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents