Heater Installation - Rinnai Energysaver RHFE-556FTR Operation And Installation Manual

Energysaver series
Hide thumbs Also See for Energysaver RHFE-556FTR:
Table of Contents

Advertisement

1. UNPACKING THE APPLIANCE
The heater is supplied in one carton containing; Heater, Standard Rear Cover Set and Bolt Pack.
Remove all packaging materials. Check for damage. If any damage is evident DO NOT install or
operate this appliance. Contact your supplier for advice. Before installing the heater, check it is
labelled for the correct gas type, (refer to the data label at the rear of the heater). Refer to the local
gas authority for confirmation of gas type if you are in doubt.
The heater does not come supplied with flue components. These are
purchased separately.
NOTE
ONLY Rinnai Energysaver
used with this appliance.
240 VOLTS, RISK OF ELECTRICAL SHOCK!
Ensure the appliance is disconnected from mains power.
WARNING
2. CONNECTING THE APPLIANCE TO THE CONSUMER GAS PIPE
1. Remove the plastic protection cap from the threaded gas inlet located at the rear of the appliance.
2. Position the appliance gas inlet in line with gas supply from wall.
3. Attach gas supply pipe to the appliance gas inlet and tighten - finger tight. Appliance has R1/2
fitting.
4. On the wall behind the appliance, at a level of about midway of the heaters height, mark the vertical
centre line of the heater.
5. Mark the flue penetration position in accordance with 'Energysaver
System Installation' manual.
6. Undo the gas connection, remove the heater.
7. Cut Flue penetration(s)
8. Mark out the securing bracket screw holes in
accordance with the drawing adjacent and table
below using the centre line as reference.
Models
RHFE-556FTR
RHFE-556FDT
RHFE-557FTR
RHFE-1004FTR
RHFE-1004FDT
9. Attach the two securing brackets supplied to the wall
using the two 8g x 30mm screws supplied, or suitable
equivalent.
10.Install flue system in accordance with 'Energysaver
Installation manual'.
11. Return the heater to the final position.
Rinnai Australia

HEATER INSTALLATION

Co-Axial Flue System Flue components can be
®
A = Width
B = Height
450
506
450
506
300
685
500
622
500
622
®
Space Heater Co-Axial Flue
Securing brackets
B
Heater Centre Line
Floor Level
SECURING
BRACKET
®
Space Heater Co-Axial Flue System