Heater Installation; Unpacking The Appliance; Connecting The Flue System - Rinnai RHFE-952ER Operation & Installation Manual

Power flued flamefire gas space heaters
Hide thumbs Also See for RHFE-952ER:
Table of Contents

Advertisement

HEATER INSTALLATION

1.

UNPACKING THE APPLIANCE

The heater components are supplied in three main cartons. These cartons contain the heater engine assembly,
the fascia and the burner media for the contents of each carton refer to "CARTON CONTENTS / ITEM
CHECKLIST" on page 4.
Check for damage and missing parts. If the heater is damaged or missing any parts, contact your supplier for
advice. Before installing the appliance, check it is labelled for the correct gas type (see label on top rear of heater).
Refer to local gas authority for confirmation of gas type if you are in doubt.
Remove the heater engine assembly from the engine carton and position in front of the enclosure opening.
2.

CONNECTING THE FLUE SYSTEM

S
1. Un-clip pipe clamp
2. Secure the telescopic extension tube
and attach the air hose
When the condensate trap kit (ESCONDK) is installed, condensate products MUST BE drained to
the heaters inbuilt condensation drain tray. With a continuous fall connect the drain hose (supplied
NOTE
with ESCONDK) from the condensate trap outlet pipe to the condensation drain tray inlet pipe
The heater does not come supplied with flue components. These are purchased separately.
ONLY the specified Rinnai flue components MUST be used with this appliance.
IMPORTANT
Connections between the heater and the flue system MUST BE made in accordance with the Rinnai
"Power Flued Flamefire Space Heater Co-axial Flue System Installation Manual" supplied with flue
kits ASPDFK or ASPKIT03.
Ensure the flue spigot of the heater is properly secured to the flue connection on the flue system
transition casting using the clip and clamp provided.
If this joint is not secured properly products of combustion could disperse into the room being
heated which may result in a dangerous condition.
Ensure the elbow of the air intake hose from the heater is properly secured to the air connection
on the flue system transition casting using the cable tie provided and that the rubber seal is placed
on the unused air intake connection of the transition piece.
3. Carefully move the heater engine into the enclosure /
cavity, guiding the consumer piping / flexible gas
connection
and telescopic extension tube
G
the access openings and through the appliance.
Ensure that the air hose
that it could be jammed behind or crushed by the
engine.
4. Once the engine is positioned home, re-connect the
flue exhaust
to the telescopic extension tube
C
and secure both together with pipe clamp
Rinnai
B
A
C
F
and remove the telescopic extension tube
A
to the flue system transition casting
B
to the flue system transition casting
F
is also not in a position
F
A
E
D
B
B
.
D
into
B
B
.
23
from the exhaust pipe
C
with the exhaust pipe lock
D
B
C
B
.
E
.
S
A
C
A
C
G
D
E
F
RHFE 952_1252 OIM