Pre-Installation Items

SECTION I - Pre-Installation Items

Code Compliance

This product must be installed in accordance to
the following:
-
All applicable local, state, national and
provincial codes, ordinances, regula-
tions and laws.
-
For installations in Massachusetts, code
requires the boiler to be installed by a
licensed plumber or gas fitter, and if
antifreeze is utilized, the installation of
a reduced pressure backflow preventer
device is required in the boiler's cold
water fill or make up water supply line.
-
For installation in Massachusetts all
direct vented appliances must comply
with the guidelines as outlined on page
11.
-
The National Fuel Gas Code NFPA54/
ANSI Z 223.1 - Latest edition.
-
National Electric Code ANSI/NFPA 70.
-
For installations in Canada -"Installation
Code for Gas Burning Equipment"
CGA/B149.1 or B149.2 Canadian
Electrical Code Part 1 CSA C22.1.
-
Standards for Controls and Safety
Devices for Automatically Fired Boilers,
ANSI/ASME CSD-1, when required.
NOTICE
The PRESTIGE boiler gas manifold and
gas controls meet the safe lighting and
other performance requirements as
specified in ANSI Z21.13 latest edition.

Determining Product Location

Before locating the PRESTIGE check for con-
venient locations to:
-
Heating system piping
-
Venting
-
Gas supply piping
-
Electrical service
Ensure the boiler location allows the combus-
tion air/vent piping to be routed directly through
the building and terminate properly outside with
a minimum amount of length and bends.
Ensure the area chosen for the installation of the
PRESTIGE is free of any combustible materi-
als, gasoline and other flammable liquids.
WARNING
Failure to remove or maintain the area
free of combustible materials, gasoline
and other flammable liquids or vapors
can result in severe personal injury,
death or substantial property damage.
Ensure the PRESTIGE and its controls are
protected from dripping or spraying water dur-
ing normal operation or service.
The PRESTIGE should be installed in a loca-
tion so that any water leaking from the boiler or
piping connections or relief valve will not
cause damage to the area surrounding the unit
or any lower floors in the structure.

Boiler Replacement

If the PRESTIGE is replacing an existing boil-
er, the following items should be checked and
corrected prior to installation:
-
Boiler piping leaks and corrosion.
-
Improper location and sizing of the
expansion tank on the boiler heating
loop.
-
If applicable, level and quality of freeze
protection within the boiler system.