Installation Instructions
1. Entry Delay No. 1 and No. 2 (fields 35, 36) cannot be greater than 30
seconds for UL Residential Burglar Alarm installations, and entry delay
plus dial delay should not exceed 1 minute. For UL Commercial Burglar
Alarm installations, total entry delay may not exceed 45 seconds.
2. For UL Commercial Burglar Alarm (Grade AA) and UL Residential
Burglar Alarm installations with line security, total exit delay time must
not exceed 60 seconds. For UL Burglar Alarm installations without line
security (Grade A), total exit delay time must not exceed 120 seconds.
3. The maximum number of reports per armed period (field 93) must be
set to "0" (unlimited) for UL installations.
4. Periodic testing (see scheduling mode) must be at least every 24 hours.
5. Alarm Sounder plus Auxiliary Power currents must not exceed 600mA
total for UL installations (Aux power 500mA max.).
6. Downloading is not permissible for UL installations.
7. If used, the audible alarm device(s) must be placed where it/they can be
heard by all users.
8. For UL commercial burglar alarm installations the control unit must be
protected from unauthorized access.
protect the control unit enclosure door is suitable for this purpose.
9. Remote downloading without an alarm company technician on-site is not
a UL Listed feature.
10. Auto-disarming is not a UL Listed feature.
9-2
UL NOTICES
The tamper switch installed to