Keypad Commands
Function
Silence alarms
Quick Arm
Single-Button arming
Alarm Memory
Arming Away
Arming Stay
Arming Night-Stay
Arming Instant
Arming Maximum
Disarming
Bypassing Zones
Forced (Quick) Bypass
Chime Mode
Activate Output Devices
SUMMARY OF ARMING MODES
Arming Mode
Exit Delay
AWAY
Yes
STAY
Yes
NIGHT-STAY
Yes
INSTANT
Yes
MAXIMUM
Yes
Panic Keys
There are three Panic keys (A, B, and C) that, if programmed, can be used to manually initiate
alarms and send a report to the central station by pressing and holding the appropriate key for at
least 2 seconds. Each key can be programmed for 24-hour Silent, 24-hour Audible, Fire, or Personal
Emergency responses. The Panic keys are identified by the system as follows:
Keys
[A] (∗/1)
[B] (∗/#)
[C] (3/#)
IMPORTANT: For a Silent panic function (if programmed) to be of practical value, you must
program a report code for the zone and the system must be connected to a central station.
Description
Pressing any key will silence the keypad sounder for 10 seconds. Disarming the
system will silence both keypad and external sounders.
If enabled (field ∗21), you can press [#] in place of the system's security code, plus
the desired arming key (Away, Stay, Instant, Maximum)
If programmed (*57 Function Key menu mode), lettered keys A-D can be used for
arming, using options 3-AWAY, 4-STAY, 5-NIGHT-STAY, or 6-Step-Arming
If used, no security code is required to arm the system.
When the system is disarmed, any zones that were in an alarm condition during
the armed period will be displayed. To clear this display, simply repeat the disarm
sequence (enter the security code and press the OFF key) again.
Enter code + AWAY [2] or simply press appropriate lettered key on the keypads
(see "Single-Button Arming" above).
Enter code + STAY [3] or simply press appropriate key on the keypads (see "Single-
Button Arming" above).
Enter code + STAY [3] + STAY [3] or simply press appropriate key on the keypads
(see "Single-Button Arming" above).
Enter code + INSTANT [7].
Enter code + MAXIMUM [4] or simply press appropriate lettered key on the
keypads (see "Single-Button Arming" above).
If entry delay or an alarm is active, you do not need to
Enter code + OFF [1].
press OFF.
Enter code + BYPASS [6] + zone number(s).
To automatically bypass all faulted zones, use the "Quick Bypass" method. Enter
code + BYPASS + [#], then wait for all open zones to be displayed. Arm when
display indicates "ZONE BYPASSED" and "READY TO ARM".
Enter code + CHIME [9]. To turn chime off, enter code + CHIME again.
If relay outputs are used, two keypad entries available to the user are included. If
programmed, these entries can be used to manually activate or deactivate the
device(s) for starting or stopping some action, such as turning lights on or off, etc.
These keypad entries are:
[Security Code] + # + 7 + [2-digit Device #] activates (starts) that device.
[Security Code] + # + 8 + [2-digit Device #] deactivates (stops) that device.
Features for Each Arming Mode
Entry Delay
Perimeter Armed
Yes
Yes
Yes
No
No
Displayed as Zone
95
99
96
Interior Armed
Yes
Yes
Yes
No
Yes
only those zones
listed in Night-
Stay zone list
Yes
No
Yes
Yes
6-5