FIELD
TITLE and EXPLANATION
AC Loss Report Code
*62
Enter the appropriate report code. Timing of this report is random with up to a 4-hour delay. If AC
restores before the report goes out, there is no "AC RESTORE" report.
UL: Required for UL commercial burglar alarm installations and required for residential fire alarm
installations.
Low Bat Report Code
*63
Enter the appropriate report code; sent when a low-battery condition exists in the system's battery.
UL: Required for UL commercial burglar alarm installations and required for residential fire alarm
installations.
Test Report Code
*64
Enter the appropriate report code, which is sent periodically to test that the communicator and phone
lines are operational. Frequency of report is set in Scheduling mode (event 11) or by the following key
commands: installer code + [#] + 0 + 0 = test report sent every 24 hours
installer code + [#] + 0 + 1 = test report sent once per week
installer code + [#] + 0 + 2 = test report sent every 28 days
Each mode sets schedule 2 to the stated repeat option; first test report sent 12 hours after command.
NOTE: Make sure the Real-Time Clock is set to the proper time before entering the test report schedule
command to ensure that test reports are sent when expected. (see Setting the Real-Time Clock section).
UL: Required for UL commercial burglar alarm installations and required for residential fire alarm
installations.
Open Report Code
*65
Enter the appropriate report code, which is sent upon disarming of the system.
UL: Required for UL commercial burglar alarm installations.
Arm Away/Stay Report Code
*66
Enter the appropriate report code.
NOTE: "OPEN" reports are not sent if the associated closing report is not enabled.
RF Trans. Low Batt. Report Code
*67
Enter the appropriate report code; sent when a wireless transmitter low-battery condition exists.
UL installations: must be enabled if wireless devices are used.
Cancel Report Code
*68
Enter the appropriate report code, which is sent upon disarming of the system after an alarm
condition was reported.
Alarm Restore Report Code
*70
Enter the appropriate report code; sent when an alarm zone is restored to its non-faulted condition.
UL: Required for UL commercial burglar alarm installations and required for residential fire alarm
installations.
Trouble Restore Report Code
*71
Enter the appropriate report code, which is sent when a trouble in a zone is restored
UL: Required for UL commercial burglar alarm installations.
Bypass Restore Report Code
*72
Enter the appropriate report code, which is sent when a zone that has been bypassed is unbypassed.
UL: Required for UL commercial burglar alarm installations.
AC Restore Report Code
*73
Enter the appropriate report code; sent when AC power has been restored after an AC power outage.
UL: Required for UL commercial burglar alarm installations and required for residential fire alarm
installations
.
Low Bat Restore Report Code
*74
Enter the appropriate report code; sent when a system low-battery condition is restored to normal.
UL: Required for UL commercial burglar alarm installations and required for residential fire alarm
installations.
RF Xmtr Low Batt. Restore Code
*75
Enter the appropriate report code, which is sent when a transmitter's low battery condition is restored
(i.e., new battery installed).
UL installations: must be enabled if wireless devices are used. Required for UL commercial burglar
alarm installations and required for residential fire alarm installations.