Odu,Enable,1:1,Red Box) Switches; Odu,Enable,1:1,Red Box) Voltages; (Odu,Enable,1:1,Csat#1) Selections (Odu,Enable,1:1,Csat#2) Selections (Odu,Enable,Stand-Alone) Selections; (Odu,Enable,1:1,Csat#1,Config) Transmitter (Odu,Enable,1:1,Csat#2,Config) - Comtech EF Data RAP-100 Installation And Operation Manual

Remote access panel
Table of Contents

Advertisement

ODU Operation
3.2.8

(ODU,ENABLE,1:1,RED BOX) SWITCHES

This menu item provides the status of both the Tx and Rx Waveguide transfer switches.
If either switch is reporting an ambiguity from the commanded position the "OK" will
change to "FT". This indicates a switch fault.
3.2.9

(ODU,ENABLE,1:1,RED BOX) VOLTAGES

This menu item provides monitor of the voltages inside the Redundancy Controller Box.
This is provided to assist in trouble-shooting system problems.
3.2.10
(ODU,ENABLE,1:1,CSAT#1)
(ODU,ENABLE,1:1,CSAT#2)
(ODU,ENABLE,STAND-ALONE)
The user is prompted from 1 of 4 sub-menu branches using the LEFT/RIGHT arrow
keys, then press ENTER.
3.2.11
(ODU,ENABLE,1:1,CSAT#1)
(ODU,ENABLE,1:1,CSAT#2)
(ODU,ENABLE,STAND-ALONE)
The user uses this menu item to select either the 'Transmitter configuration branch",
"Receiver configuration branch" or "Miscellaneous configuration branch". Use the
LEFT/RIGHT arrow keys, then press ENTER.
3.2.12
(ODU,ENABLE,1:1,CSAT#1,CONFIG)
(ODU,ENABLE,1:1,CSAT#2,CONFIG)
(ODU,ENABLE,STAND-ALONE,CONFIG)
This menu item is used to select which ODU Transmitter parameter is to be modified.
Use the LEFT/RIGHT arrow keys, then press ENTER.
3–4
WAVEGUIDE SWITCH STATUS:
TX=OK
RX=OK
REDUNDANCY BOX VOLTAGES:
5V= X.X
12V=XX.X
ODU SELECT: CONFIG
MONITOR
ALARMS
ODU CONFIG: TRANSMITTER
RECEIVER
MISCELLANEOUS
ODU TX: FREQUENCY
AMPLIFIER
MUTE
Selections
Selections
Selections
INFO
(ENTER)
CONFIG (Confiuration)
CONFIG (Confiuration)
CONFIG (Confiuration)
TRANSMITTER
TRANSMITTER
TRANSMITTER
ATTEN
SLOPE
RAP-100 Remote Access Panel
Rev. 1

Advertisement

Table of Contents
loading

Table of Contents