Toshiba RAS-10G2KVP-E Service Manual page 70

Split type
Table of Contents

Advertisement

Bend the connecting pipe within a radius of 30 mm.
To connect the pipe after installation of the unit
(figure)
To connect the pipe after installation of the unit
(figure)
Reference position of Liquid side and Gas side's
piping on Installation Plate.
Marking label
(42 mm)
Gas side
Liquid side
R 30 mm (Use polisin (polyethylene) core
or the like for bending pipe.)
Fig. 10-3-14
NOTE :
If the pipe is incorrectly, the indoor unit may
unstably be set on the wall.
After passing the connecting pipe through the pipe
hole, connect the connecting pipes to the auxiliary
pipes and wrap the facing tape around them.
CAUTION
Bind the auxiliary pipes (two) and connecting cable
with facing tape tightly. In case of leftward piping
and rear-leftward piping, bind the auxiliary pipes
(two) only with facing tape.
Auxiliary
pipes
Installation
plate
Carefully arrange pipes so that any pipe does not
stick out of the rear plate of the indoor unit. Carefully
connect the auxiliary pipes and connecting pipes to
one
another and cut off the insulating tape wound on the
connecting pipe to avoid double-taping at the joint;
moreover, seal the joint with the vinyl tape, etc.
• Since dewing results in a machine trouble, make
sure to insulate both connecting pipes. (Use
polyethylene foam as insulating material.)
When bending a pipe, carefully do it, not to crush it.
Outward form of indoor unit
Use the handle of screwdriver, etc.
Indoor
unit
Connecting
cable
10-3-4. Indoor Unit Fixing
1. Pass the pipe through the hole in the wall and hook
the indoor unit on the installation plate at the upper
hook.
Swing the indoor unit to right and left to confirm that it
is firmly hooked up on the installation plate.
While pressing the indoor unit onto the wall, hook it at
the lower part on the installation plate. Pull the indoor
unit toward you to confirm that it is firmly hooked up
on the installation plate.
Hook here.
1
Hook
For detaching the indoor unit
from the installation plate, pull
the indoor unit toward you
while pushing its bottom up at
the specifi ed parts.
10-3-5. In case of Indoor unit is fi xed to
Installation plate with screws
1.
Remove 2 screw caps with flat screwdriver.
2.
Fix them with ∅4x10~14L, 2 screws which are
prepared at the site.
3.
Cover screw caps as previous process.
Screw cap
69
FILE NO. SVM-14017
Installation plate
Installation plate
Hook
Push
Fig. 10-3-15
<How to remove>
<How to fix>
Flat screwdriver
Fig. 10-3-16
Push
Push