NOTE: IF THE WIRE DRESSING IS NOT DONE PROPERLY, IT MAY CAUSE DISTORTION
CHASSIS WIRE DRESSING DETAIL -1
CHASSIS WIRE DRESSING DETAIL -2
KD-32XS945
CABLE WIRE DRESSING
x3 11mm purselock (p/n: 3-703-983-02)
(NOTE positions of purselocks on main cable bundle.)
CRITICAL POINT:
Main cable bundle MUST be dressed as LOW
as possible between cement resistor and heat sink.
Wires cannot touch heat sink (sharp edges) or the
cement resistor (very hot).
1-900-805-24 ground wire attached here
on Antenna Switch
Pin Plug Cable 1-534-630-23
conect like this
Add gasket nect to connection with
W-box (avoid cable touching shield case)
KD-32XS945