TRANSMITTER ADJUSTMENTS—continued
ADJUSTMENT
ADJUSTMENT CONDITION
1
• Displayed freq. : 14.10000 MHz
HF BANDS
OUTPUT
• Mode
POWER
• [RF POWER] : Max. CW
• [TUNER]
• Transmitting
50 M BAND
1
• Displayed freq. : 51.00000 MHz
OUTPUT
• Mode
POWER
• [RF POWER] : Max. CW
• [TUNER]
• Transmitting
144 M BAND
1
• Displayed freq. : 145.00000 MHz
OUTPUT
• Mode
• [RF POWER] : Max. CW
POWER
• [TUNER]
• Transmitting
AM
1
• Displayed freq. : 14.10000 MHz
• Mode
CARRIER
• [RF POWER] : Max. CW
• [MIC GAIN]
• Apply no audio signals to [MIC]
connector.
• Transmitting
AM
1
• Displayed freq. : 14.10000 MHz
MODULATION
• Mode
• [MIC GAIN]
• [RF POWER] : Max. CCW
• Connect an audio generator to
[MIC] connector and set as:
Frequency
Level
• Transmitting
FM
1
• Displayed freq. : 28.50000 MHz
DEVIATION
• Mode
• Tone
• [RF POWER] : Max. CW
• [MIC GAIN]
• Connect an audio generator to
[MIC] connector and set as:
Frequency
Level
• Transmitting
RESIDUAL
1
• Displayed freq. : 145.00000 MHz
AM
• Mode
• Tone
• [RF POWER] : Max. CW
• [MIC GAIN]
• Connect an audio generator to
[MIC] connector and set as:
Frequency
Level
• Transmitting
SWR
• Displayed freq. : 29.70000 MHz
• Mode
DETECTOR
• [RF POWER] : Max. CW
• [TUNER]
• Connect CP7 (SETI) on the CTRL
unit to GND.
• Connect a 50 Ω dummy load or an
RF power meter to [ANT1] connector.
• Transmitting
After adjustment, disconnect CP7 (CTRL unit) from GND.
MEASUREMENT
UNIT
Rear
: RTTY
panel
: OFF
Rear
: RTTY
panel
: OFF
Rear
: RTTY
panel
: OFF
Rear
: AM
panel
: Center
Rear
: AM
panel
: Center
: 1 kHz
: 10 mVrms
Rear
: FM
panel
: OFF
: Center
: 1 kHz
: 10 mVrms
Rear
: FM
panel
: OFF
: Center
: 1 kHz
: 4.5 kHz deviation
at the connected
deviation meter.
CTRL
: FM
: OFF (Through)
5 - 6
VALUE
LOCATION
Connect
an
RF
power
meter
to
[ANT1] connector.
Connect
an
RF
power
meter
to
[ANT1] connector.
Connect
an
RF
power meter to [ANT
144MHz] connector.
Connect
an
RF
power meter to [ANT
144MHz] connector.
Connect a modulation
100% or less
analyzer to [ANT1]
connector through an
attenuator.
Connect an FM devi-
4.5 kHz ±0.3 kHz
ation meter to [ANT1]
connector through an
attenuator.
Connect an FM devi-
Minimum RESIDUAL
ation meter to [ANT
144MHz] connector
through an attenua-
tor.
Connect
a
digital
Minimum voltage
multimeter or oscillo-
scope to the check
point CP1.
ADJUSTMENT
POINT
UNIT
ADJUST
100 W
MAIN
R306
100 W
MAIN
R311
100 W
MAIN
R317
40 W
MAIN
R320
Verify
Verify
RF
L252,
AM level
L251,
CTRL
C3

Hide quick links: