Trouble Shooting Checklist; Error Codes - Rinnai RHFE-752ETR Operation & Installation Manual

Power flued flamefire gas space heater
Hide thumbs Also See for RHFE-752ETR:
Table of Contents

Advertisement

TROUBLE SHOOTING CHECKLIST

Use the following chart to help determine whether a service call is required, however if you are unsure
about the way your heater is operating, contact Rinnai or your local agent.
Fault
Condition
Probable
Cause
Not plugged in or turned off.
Mains power failure.
(Initial Install) Air in gas pipe.
Filter obstructed.
Gas escape.
On Timer set.
Lock set.
Gas supply turned off.
Flat batteries.
Remote Control lock-up due
to mis operations such as
the remote signal being out
of range, incorrectly aimed
or obstructed.

ERROR CODES

Your Rinnai space heater is also fitted with self diagnostic electronics that
monitor the appliance during start-up and operation.
Should a fault occur the heater will shut down, the fault that has caused the
shut down will be indicated by a pair of flashing digits in the Error Display
window and a 'Green' flashing Operation Indicator
Refer to the table below for probable cause and the suggested remedy.
Code
Probable Cause
00
Mains power failure
11
Ignition failure
12
Incomplete combustion
14
Filter Blockage / Overheat
16
Room overheat
31
Room temperature sensor faulty
32
Overheat temperature sensor faulty
33
Overheat temperature sensor faulty
53
Spark sensor faulty
61
Combustion fan motor faulty
71
Solenoids faulty
72
Flame detection circuit fault
73
Communication error
Rinnai
CARE AND MAINTENANCE
To reset the heater, press the On/Off
the remote control and press the STANDBY/ON
once for stand-by mode, press the STANDBY/ON
button a second time to set the heater to On.
Check gas supply is turned on, switch the heater to Standby
and then On again. If ignition failure continues to occur a
Service call will be required.
As above
Clean filters, if error continues service call.
Lower room temp to below 40°C.
Service call.
Service call.
Service call.
Service call.
Service call.
Service call.
Service call.
Service call.
Possible Remedy
Plug in power cord or press On/Off
Use power failure reset procedure on page 7.
Installer to purge air from gas supply.
Remove and clean filters.
Isolate gas supply, call Rinnai service, page 28.
Use the Override as described on page 11.
Cancel Lock as described on page 11.
Turn gas supply on at the meter or cylinder.
Replace remote control batteries 2 x 1.5v (AAA).
Press the STANDBY/ON
.
8
Suggested Remedy
14
button.
button.
11
10
8
7
10
STANDBY
11
ON
button twice or use
button
11
11
Operation Manual