Cornelius Vanguard 245 Service Manual page 57

Post-mix
Hide thumbs Also See for Vanguard 245:
Table of Contents

Advertisement

C
ONDENSER
1. Shut off water and CO
2. Remove the hood by removing screws on the top and lifting up.
3. Disconnect power to the unit.
4. Remove cover by removing two
mounting screws.
5. Unplug harness.
6. Lift up condenser assembly cover
by loose four mounting screws.
7. Remove four mounting screws
of motor bracket.
8. remove fan motor by disassembling
three motor mounting screws.
9. Install new fan motor by reversing this procedure.
301135000E
F
M
R
AN
OTOR
at their sources.
2
EPLACEMENT
Mounting
screws of
cover
Harness
Mounting
screws of
condenser
assembly
Mounting screws
of motor bracket
Mounting screws
of motor
- 51 -
Vanguard 245 Service Manual
© 2006, IMI Cornelius Inc.