Hot-water temperature for 600 - 24 C
Range of application
Minor convenience, small heat losses
Average convenience, medium heat losses
Optimum convenience, normal heat losses
Table 3
Hot-water temperature in external tanks
6.2
Combustion fuels
Natural gas or propane.
6.3
Frost hazard for the heating system
In the event of any risk of the heating system freezing
up:
Open the control panel cover.
Open cover for 2nd control box (fig. 9, item 1).
Move switch to
position "2" (pump post-purge
period 24 h) (fig. 9, item 5).
Shut cover for 2nd control box and control panel.
Subject to modifications resulting from technical improvements!
8
DWH-storage temperature [°C]
40
43
46
49
52
55
58
60