Sleep Mode - Pride Mobility Jazzy 1121 Owner's Manual

Wheelchair
Hide thumbs Also See for Jazzy 1121:
Table of Contents

Advertisement

Actuator Lighting Module (Not Shown)
The actuator lighting module is also located on the power base. The actuator lighting module provides a control and power interface
between the power module, the lights, and/or the power seat actuator.

Sleep Mode

Your Remote Plus controller has a sleep mode feature. Sleep mode is a built-in circuit that automatically shuts off the main
power if the joystick is not moved in any direction for approximately five minutes. The battery condition meter lights on the
keypad indicate sleep mode by blinking once every five seconds. To restore power and continue, push the on/off key twice.
Thermal Rollback
The Remote Plus is equipped with a thermal rollback circuit. This circuit monitors the temperature of the motors, power
module, and remote. In the event that any of them become excessively hot (above 50° C/122° F), motor voltage is reduced. For
every degree above 50°C/122° F, the voltage is reduced by 5 volts. This reduces your power chair's speed and allows the
electrical components to cool down. When the temperature returns to a safe level, your power chair resumes its normal speed.
Trouble Codes
In addition to indicating the current state of battery charge, the battery condition meter can also indicate possible problems with
your power chair. The battery condition meter has ten lights. The lights provide information by the number of lights that are
flashing. If any of the meter lights are flashing rapidly, the controller may be indicating a fault. For instance, if the first light is
flashing rapidly, the battery voltage is nearly depleted. The following is a list of the possible errors signified by the rapidly
flashing meter. When you get a trouble code, contact your authorised Pride provider.
FLASHING LIGHTS
10
9
8
7
6
5
4
3
2
1
32
V I I .
O P E R A T I O N
DIAGNOSIS
High Battery Voltage
Solenoid Brake Fault
Possible Controller Fault
Possible Joystick Fault
Inhibit Active
Right Motor Wiring Fault
Right Motor Disconnected
Left Motor Wiring Fault
Left Motor Disconnected
Low Battery Voltage
WWW.PRIDEMOBILITY.COM
SOLUTION
Check batteries.
Check motor/brake wiring.
See authorised Pride provider.
See authorised Pride provider.
Unplug charger. Check connections.
Check right motor wiring.
Check right motor wiring.
Check left motor wiring.
Check left motor wiring.
Check batteries/battery wiring.
JAZZY1121/REV C/SEPTEMBER 2002

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents