Optional Equipment
4.
Install the LP pilot orifice following the directions below.
(a) Use a 7/16" open-end wrench to remove the pilot hood.
(b) Remove and discard the Natural Gas (NG) orifice. Place the LP orifice in the pilot assembly then replace the pilot
hood, tightening the pilot hood until it is snug (do not over-tighten).
a
5.
Remove the concealment cover. Unscrew the four screws holding the control cover in place. Carefully remove
the control cover and place face down to access the regulator.
6.
Disconnect the regulator wire from the IFC. Pinch the tab on the wire connector to release.
7.
The stepper motor (adjustable regulator) has an installation sheet included with it – make sure to follow all of the
directions. Place the stepper motor on the gas control valve– MAKE SURE IT IS CORRECTLY ORIENTED.
Secure using the screws included with the motor– tighten to 25 Lb-inches. Leak test this area after installation to
verify proper installation.
8.
Install the burner (see the instructions included with the burner). Replace the glass and restore the
fireplace to the correct configuration.
Travis Industries
(
for qualified installers only)
Natural Gas Orifice = .020N (3way)
.018N (2way)
LP (Propane) Orifce = .014LP
7/16" Wrench
4121206
b
.020N
or
.018N
.014LP