Vent Configurations with Vertical Termination (EmberFyre Burner only)

The termination must fall
within the shaded area
shown in the chart. Use the
indicated restrictor and
diffuser positions.
Up to four elbows (45° or
90°) may be used.
Only one horizontal elbow
may be used.
Horizontal length (max. 24') is calculated
by adding both lengths of horizontal run
(Horizontal Length = H1 + H2).
This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.
H2
.
H1
This is considered a vertical elbow.
Travis Industries
Installation
(
40' max (12m)
35 feet (10.5m)
30 feet (9m)
25 feet (7.5m)
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet
for qualified installers only)
Exhaust Restrictor #5
Intake Restrictor #6
Diffuser #2 (OPEN)
Exhaust Restrictor #4
Intake Restrictor #5
Diffuser #2 (OPEN)
Exhaust Restrictor #2
Intake Restrictor #2
Diffuser #2 (OPEN)
Exhaust Restrictor #1
Intake Restrictor #2
Diffuser #2 (OPEN)
4121206
40' max (12m)
35 feet (10.5m)
30 feet (9m)
Exhaust Restrictor #3
25 feet (7.5m)
Intake Restrictor #3
Diffuser #2 (OPEN)
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
Exhaust Restrictor #1
Intake Restrictor #1
Diffuser #1
5 feet (1.5m)
0 feet