22
Vent Configurations with Vertical Termination (EmberFyre Burner only)
•
The termination must fall
within the shaded area
shown in the chart. Use the
indicated restrictor and
diffuser positions.
•
Up to four elbows (45° or
90°) may be used.
•
Only one horizontal elbow
may be used.
Horizontal length (max. 24') is calculated
by adding both lengths of horizontal run
(Horizontal Length = H1 + H2).
This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.
H2
.
H1
This is considered a vertical elbow.
Travis Industries
Installation
(
40' max (12m)
35 feet (10.5m)
30 feet (9m)
25 feet (7.5m)
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet
for qualified installers only)
Exhaust Restrictor #5
Intake Restrictor #6
Diffuser #2 (OPEN)
Exhaust Restrictor #4
Intake Restrictor #5
Diffuser #2 (OPEN)
Exhaust Restrictor #2
Intake Restrictor #2
Diffuser #2 (OPEN)
Exhaust Restrictor #1
Intake Restrictor #2
Diffuser #2 (OPEN)
4121206
40' max (12m)
35 feet (10.5m)
30 feet (9m)
Exhaust Restrictor #3
25 feet (7.5m)
Intake Restrictor #3
Diffuser #2 (OPEN)
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
Exhaust Restrictor #1
Intake Restrictor #1
Diffuser #1
5 feet (1.5m)
0 feet
100-01327
22