Gasket Replacement; Inspect The Vent System Annually; Check The Gas Flame Regularly - Vermont Castings 3225 Installation And Operating Manual

Radiance direct vent/natural vent gas heater
Hide thumbs Also See for 3225:
Table of Contents

Advertisement

Fig. 65 Release the latches to remove the glass frame.

Gasket Replacement

The Radiance Gas Heater uses a 'tadpole' type gasket
to seal between the glass panel and the frame. In time,
this gasket can become brittle and compressed and
should be replaced. New gasket is available from your
dealer.
Shut off the gas supply and allow the stove to cool.
Wear safety goggles and a dust mask.
1. Remove the Front, Glass Frame and Glass Panel.
(Figs. 62 & 63) Remove the old gasket. Use a
razor blade to separate the glass and gasket from
the frame, and to clean the glass of any remaining
cement or bits of gasket. Use a cold chisel if neces-
sary.
2. Determine the correct length of gasket by laying it
out around the edge of the glass. Allow an extra 1
- 2" (25-50mm). Mark the spot to be cut. Use a utility
knife.
3. Starting on a long edge, remove about 6" of the pro-
tective paper strip and apply the flat adhesive face
of the gasket around the outside-facing edge of the
panel. Continue around the panel, applying a bout 6"
at a time and being careful to not stretch the mate-
rial. Do not overlap the gasket ends. (Fig. 66)
4. Apply a thin bead of high temperature silicone
rubber sealant along the inside corner of the glass
frame, all around the perimeter. Place the flat
gasketed side of the glass panel back into the steel
frame. Pinch the rounded inside-facing gasket mate-
rial to bulk it up.
5. Replace the glass frame and front panel as previ-
ously described.
20004188
ST141
ST141
pull glass latch
10/99
Radiance Direct Vent /Natural Vent Gas Heater
Fig. 66 Wrap the gasket material around the outside edge of
the glass.

Inspect the Vent System Annually

ST179
glass gasket detail
Have the vent system inspected annually by a quali-
11/99
fied technician. Shut off the main gas supply before
inspecting the system. Both the inner exhaust pipe and
the outer combustion supply pipe must be checked to
confirm that they are unblocked and in good condition.

Check the Gas Flame Regularly

To ensure that the stove is operating properly, check
the flames periodically to confirm that they match
Figure 67. The flames will be blue during the first 15-20
minutes of operation, and will gradually turn to yellow
after that.
Do not use your stove if the flame pattern differs from
that shown here. Contact your Vermont Castings dealer
or a qualified technician for help.
Red
Glow
Fig. 67 Correct flame pattern.
LG157
Radiance logs
flame
4/24/01 djt
ST179
LG157
35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents