INSTRUCTION MANUAL FOR DISHWASHERS
machine ready indicator lamp blinks red. The machine ready time decreases.
o If the function is not enabled, the tank starts to fill directly from the line and the machine
ready indicator lamp blinks green.
Energy-Saving: allows electric energy to be saved in the case of stand-by while keeping the
water temperature at a value strictly dependent on the chosen cycle.
Thermostop: allows the optimum rinsing temperature to be reached before the end of the
washing cycle in progress.
Tank operating temperature: can be set between 45°C and 70°C.
Boiler operating temperature: can be set between 65 °C and 90 °C.
The number of cycles between one regeneration and the next has to be established based on the
hardness of the water in the installation area, following the table given below.
No.
dH
F
Cycles
8,0
14
100
8,5
15
90
9,0
16
77
9,5
17
74
10,0
18
71
10,5
19
68
To change the number of cycles:
1. Turn off and turn back on the machine while keeping the on/off button pressed for about 5
seconds.
2. The message "SET" alternating with the tank and boiler setting temperatures appears on the
display.
3. Press the on/off button once again to make the number of set cycles appear.
TANK
-
6. Set the number of cycles to zero to deactivate the regeneration indicator.
7. Press the on/off button to return to the machine ready condition.
8. Run a final regeneration cycle.
Only qualified and authorised technical personnel can perform deinstallation.
• Turn off the power to the machine with the external main switch.
• Shut off the external water supply tap.
• Completely disconnect the machine from the electric and water supply networks.
• Empty, clean and completely prepare all the internal water circuits, measuring devices, pumps
and boiler.
• Completely empty the detergent and rinse aid dispensers and tubes connected to them, making
sure to correctly dispose of the detergent and rinse aid (contact the supplier of the products
used)
No.
dH
F
Cycles
11,0
20
65
12,0
21
62
12,5
22
59
13,0
23
56
13,5
24
53
14,0
25
50
4. "Cycle selection" button to reduce the number of set
BOILER
START
5. "Cycle start" button to increase the number of set
+

6.2.1 Number of cycles for resin regeneration

No.
dH
F
Cycles
14,5
26
47
15,0
27
44
15,5
28
41
16,0
29
38
17,0
30
35
17,5
31
32
cycles (min = 1);
cycles (max = 99);

Chap 7 DEINSTALLATION

GB
No.
dH
F
Cycles
18,0
32
29
18,5
33
26
19,0
34
23
19,5
35
20