D. Mantel Projections
Figure 3.3
Fire Risk
Comply with all minimum clearances to combustibles as specifi ed.
Framing or fi nishing material used on the front of, or in front of, the appliance closer than the minimums
listed, must be constructed entirely of noncombustible materials (i.e., steel studs, concrete board, etc.).
Failure to comply may cause fi re.
7
6
5
7-3/4
4
7
3
6-1/4
5-1/2
5
Clearances to Mantels or Other Combustibles Above Appliance
Top of
Appliance
A
B
Figure 3.4
Clearances to Combustible Mantel Legs or Wall Projec-
tions (acceptable on both sides of opening)
Heatilator • Novus BV • 4031-551 Rev B • 12/06
14
13
12
13
11
12-1/4
10
11-1/2
9
10-3/4
8
10
9-1/4
8-1/2
Measured from top of hood (in inches)
Drywall
A
48 in.
(1219 mm)
max.
B
Mantel Leg or
Perpendicular Wall
1 in. (25 mm) min.
to perpendicular wall
3-1/2 in. (89 mm) min.
from fireplace opening
to perpendicular wall
WARNING
32-1/2 in. minimum
to ceiling
18
17
16
16
15
15-1/4
14-1/2
13-3/4
11