Heatilator NBV3630I Owner's Manual
Hide thumbs Also See for NBV3630I:
Table of Contents

Advertisement

Quick Links

Model(s):
NBV3630I, NBV3933I,
NBV4236I, NBV4842I
B-Vent Gas Appliance
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
DANGER
HOT GLASS WILL
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
A CO detector shall be installed in the room where the appliance
in installed.
Installation and service of this
appliance should be performed by
qualifi ed personnel. Hearth & Home
Technologies recommends HHT
Factory Trained or NFI certified
professionals.
CAUSE BURNS.
UNTIL COOLED.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heatilator NBV3630I

  • Page 1 Installation and service of this appliance should be performed by qualifi ed personnel. Hearth & Home  Technologies recommends HHT Factory Trained or NFI certified professionals. Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 2: Congratulations

    MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX XXXXXXXX XXXXXXXX (Serie): (Serie):  = Contains updated information. Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 3: Table Of Contents

    A. Vent Guidelines C. Optional Components B. Vent System Confi guration D. Contact Information 8 Vent Clearances and Framing A. Pipe Clearances to Combustibles B. Wall and Ceiling Penetration Framing Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 4: Warranty

    3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645G 2/15 Page 1 of 2 Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 5 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645G 2/15 Page 2 of 2 Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 6: Listing And Code Approvals

    NBV4842 Max/Min Input Rate (NG) 25,000/17,000 30,000/20,500 Orifi ce Size (NG) 0.093 (#42) 0.104 (#37) Max/Min Input Rate (LP) 25,000/17,000 30,000/20,500 Orifi ce Size (LP) 0.058 0.063 (#52) Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 7: User Guide

    • Install a switch lock or a wall/remote control with child protection lockout feature. • Keep remote controls out of reach of children. Figure 2.1 General Operating Parts Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 8: Fan Kit (Optional)

    F. Fixed Glass Assembly See Section 14.J. G. Remote Controls, Wall Controls and Wall Switches Follow the instructions supplied with the control installed to operate your fi replace: Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 9: Lighting Instructions (Ipi)

    Keep burner and control compartment clean. See installation and operating instruc- Propane Installation code, CSA B149.1. tions accompanying appliance. For additional information on operating your 593-913i Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 10: After Fireplace Is Lit

    fl ame burn continually? Some optional control systems available with IPI models may allow pilot fl ame to remain lit. In a standing pilot system the pilot will always stay on. Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 11: Maintenance And Service

    Carefully set fi xed glass assembly in place on fi replace. Hold glass in place with one hand and secure glass latches with the other hand. • Reinstall door or decorative front. Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 12: Maintenance Tasks-Qualifi Ed Service Technician

    Use caution when cleaning these areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided. • Remove all foreign objects. • Verify unobstructed air circulation. Figure 3.1 IPI Pilot Flame Patterns Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 13: Installer Guide

    Ceiling Joists (SECTION 5) (SECTION 8) Optional Wall Switch Mantel & Mantel Leg (SECTION 13) Surround Hearth Extension (not required) Gas Line (SECTION 11) Figure 4.1 Typical System Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 14: Design And Installation Considerations

    Call a qualifi ed service technician to inspect the appli- ance and to replace any part of the control system and/or gas control which has been under water. Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 15: Negative Pressure

    Ensure adequate outdoor air is supplied for combustion appliances and exhaust equipment. Recommended Recommended Location Location Marginal Location Location Recommended Location Recommended Windward Leeward Multi-level Roofs Figure 4.2 Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 16: Framing And Clearances

    8-1/2 NBV3630I inches 35-1/2 19-5/8 9-1/2 NBV3933I 1016 inches 37-5/8 19-5/8 10-5/8 NBV4236I 1067 1092 inches 41-7/8 19-5/8 12-3/4 NBV4842I 1219 1064 1245  Figure 5.1 Appliance Locations Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 17: Constructing The Appliance Chase

    (Height) (Depth) Model 34-7/8 19-5/8 NBV3630I 34-7/8 19-5/8 NBV3933I 36 in. (914 mm) 34-7/8 19-5/8 0 in. NBV4236I 1067 34-7/8 19-5/8 NBV4842I 1219 Figure 5.2 Clearances to Combustibles Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 18: Mantel And Wall Projections

    3-1/2 in. (89 mm) min. from fireplace opening to perpendicular wall Figure 5.4 Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening) Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 19: Termination Locations

    Over 18/12 to 20/12 Over 10/12 to 11/12 3.25 Over 20/12 to 21/12 * 3 ft. minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 20: Vent Information And Diagrams

    Failure to keep insulation or other material away from vent Elbow pipe may cause fi re. Note: Maximum horizontal distance is 50% of vertical vent height. Figure 7.3 Maximum Horizontal Run Using 45° Elbows Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 21: Vent Clearances And Framing

    2 in. (51 mm) above insulation. Attic shields must meet specifi ed clearance and be se- cured in place. Use B-vent manufacturer’s fi restops to provide adequate clearances. Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 22: Appliance Preparation

    Secure the appliance to the fl oor by inserting two screws through the bottom front of the appliance. Figure 9.1 Outside Air Kit Installation Nailing Flanges (both sides) Figure 9.2 Proper Positioning ad Securing of Appliance Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 23: Installing Vent Pipe

    2 in. (51 mm) above insulation. Attic shields must meet vent manufacturer’s specifi ed clearance and be secured in place per vent manufactur- er’s instructions. Figure 10.1 Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 24: Gas Information

    In CANADA: Reduce burner orifi ce 10% for elevations valve inlet. between 2000 feet and 4500 feet. Above 4500 feet, • If substituting for these components, please consult consult local gas utility. local codes for compliance. Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 25: Electrical Information

    • Wiring for optional Hearth & Home Technologies approved accessories should be done now to avoid reconstruction. Follow instructions that come with those accessories. Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 26: Electrical Service And Repair

    Pilot Assembly Optional Remote Junction Limit Switch Adaptor GRN* * GRN wire only used with optional wall switch WSK-MLT-HTL Valve Figure 12.2 Intellifi re Pilot Ignition (IPI) Wiring Diagram Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 27: Junction Box Installation

    (switch leg) wire, route it through the knockout in the face of the junction box, and connect to the top fan switch connector (1/4 in. male) as shown. Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 28: Finishing

    3-1/2 in. (89 mm) min. from fireplace opening to perpendicular wall Figure 13.2 Combustible Mantel Leg or Wall Projections (Accept- able on both sides of opening) Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 29: Facing Material

    Overlapping materials could ignite and will inter- fere with proper operation of doors and louvers. These surfaces may be covered with non-combustible Non-combustible material. sealant. Figure 13.3 Noncombustible Facing Diagram Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 30: Appliance Setup

    Hearth & Home Technologies-approved optional acces- sories with this appliance. Using non-listed accessories could result in a safety hazad and will void the warranty. Figure 14.3 Remove Screen Package Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 31: Place The Rockwool

    Set the glass panel on the lower two or four glass assembly latches, ensuring the glass panel is centered in the opening. • Replace glass latches. See Figure 14.4. Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 32: Remove Screen Protector

    Figure 14.7 Cut Packaging Tape Figure 14.10 Installing Hood Figure 14.8 Remove Screen Protector M. Unpackage the Hood Remove hood from appliance as shown in Figure 14.9. HOOD Figure 14.9 Removing Hood Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 33: Close The Screen Assembly

    Figure 14.13 Rotate the Screen Down Figure 14.11 Magnetic Touch Latch Open Hang Screen on Shoulder Screws Figure 14.14 Press on Bottom of Screen Figure 14.12 Hang Screen Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 34: Troubleshooting

    Verify module is securely grounded to metal chassis of appliance. d. Module voltage output / Valve/Pilot Verify battery voltage is at least 2.7 volts. Replace batteries if volt- solenoid ohms readings. age is below 2.7. Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 35 ON position. If there is no spark at “I” terminal module must be replaced. If there is a spark at “I” terminal, module is fi ne. Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 36: Reference Materials

    (38 mm) (203 mm) 15-3/4 in. (400 mm) Model inches 8-5/8 NBV3630I inches 11-5/8 NBV3933I inches 14-5/8 NBV4236I 1041 inches 20-5/8 NBV4842I 1194 1067 Figure 16.1 Appliance Dimensions Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 37: Service Parts

    B. Service Parts Service Parts Beginning Manufacturing Date: Feb 2008 Novus Gas Fireplace - BV Ending Manufacturing Date: Active Log Set Assembly Part number list on following page. 09/14 Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 38 Conversion Kit LP DCKVP-Novus Pilot Ori ce NG 593-528 Pilot Ori ce LP 593-527 Regulator NG NGK-DXV Regulator LP LPK-DXV Additional service part numbers appear on following page. Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 39 Conversion Kit LP DCKVP-Novus Pilot Ori ce NG 593-528 Pilot Ori ce LP 593-527 Regulator NG NGK-DXV Regulator LP LPK-DXV Additional service part numbers appear on following page. Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 40 Conversion Kit LP DCKVP-Novus Pilot Ori ce NG 593-528 Pilot Ori ce LP 593-527 Regulator NG NGK-DXV Regulator LP LPK-DXV Additional service part numbers appear on following page. Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 41 DCKVP-Novus Conversion Kit LP Pilot Ori ce NG 593-528 Pilot Ori ce LP 593-527 Regulator NG NGK-DXV Regulator LP LPK-DXV Additional service part numbers appear on following page. Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 42 NBV3933i Ori ce LP (#54C) 582-854 Ori ce NG (#42C) 582-842 NBV4236i Ori ce LP (0.058) 4021-602 Ori ce NG (#37C) 582-837 NBV4842i Ori ce LP (#52C) 582-852 Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 43: Optional Components

    [432 mm] 9-3/8 in. [238 mm] LDS-BV Decorative Shroud TCG375 Terra Cotta Cap Catalog # 12.5 15.5 LDS-BV See your Heatilator dealer for a complete listing of optional components. Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...
  • Page 44: Contact Information

    5941237, 6006743, 6019099, 6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729, 8147240 or other U.S. and foreign patents pending. 2000-945C Printed in U.S.A. - Copyright 2015 Heatilator • Novus B-Vent Series • 4055-188 • Rev. X • 9/15...

This manual is also suitable for:

Nbv3933iNbv4236iNbv4842i

Table of Contents