Daikin R-410A Service Manual page 24

Vrv ii-sr-410a heat pump 50hz
Hide thumbs Also See for R-410A:
Table of Contents

Advertisement

Specifications
Ceiling Mounted Duct Type
Model
H1 Cooling Capacity (19.5°CWB)
H2 Cooling Capacity (19.0°CWB)
H3 Heating Capacity
Casing
Dimensions: (H×W×D)
Rows×Stages×Fin Pitch
Coil (Cross
Fin Coil)
Face Area
Model
Type
Motor Output × Number
of Units
Fan
Air Flow Rate (H/L)
External Static Pressure
Drive
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Liquid Pipes
Gas Pipes
Piping
Connections
Drain Pipe
Machine Weight
H7 Sound Level (H/L)
Safety Devices
Refrigerant Control
Connectable outdoor unit
Standard Accessories
Drawing No.
Notes:
H1 Indoor temp. : 27°CDB, 19.5°CWB / outdoor temp.: 35°CDB / Equivalent piping length: 7.5m,
H2 Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp.: 35°CDB / Equivalent piping length: 7.5m,
H3 Indoor temp. : 20°CDB / outdoor temp.: 7°CDB, 6°CWB / Equivalent piping length; 7.5m,
H4 Static external pressure is changeable to change over the connectors inside electrical box, this pressure
H5 Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its
6 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
H7 Anechoic chamber conversion value, measured at a point 1.5m downward from the unit center. These
14
FXMQ80MVE
kcal/h
8,000
Btu/h
31,800
kW
9.3
kW
9.0
kcal/h
8,600
Btu/h
34,100
kW
10.0
Galvanized Steel Plate
mm
390×720×690
mm
3×16×2.0
0.181
D11/2D3AA1VE
Sirocco Fan
W
160×1
m³/min
19.5/16
cfm
688/565
157/160-108/98 H4
Pa
Direct Drive
Microprocessor Thermostat for
Cooling and Heating
Glass Fiber
H5
φ9.5 (Flare Connection)
mm
φ15.9 (Flare Connection)
mm
VP25
mm
(
External Dia. 32
Internal Dia. 25
kg
45
dBA
42/38
Fuse,
Thermal Fuse for Fan Motor
Electronic Expansion Valve
R410A M Series
Operation Manual, Installation Manual,
Drain Hose, Clamp Metal, Insulation
for Fitting, Sealing Pads, Clamps,
Screws.
level difference: 0m.
level difference: 0m.
level difference; 0m. (Heat pump only)
means "High static pressure-Standard".
colorimetric method (gravity method) 50% or more.
values are normally somewhat higher during actual operation as a result of installation conditions.
FXMQ100MVE
10,000
39,700
11.6
11.2
10,800
42,700
12.5
Galvanized Steel Plate
390×1,110×690
3×16×2.0
0.319
2D11/2D3AG1VE
Sirocco Fan
270×1
29/23
1,024/812
157/172-98/98 H4
Direct Drive
Microprocessor Thermostat for
Cooling and Heating
Glass Fiber
H5
φ9.5 (Flare Connection)
φ15.9 (Flare Connection)
VP25
)
(
External Dia. 32
Internal Dia. 25
63
43/39
Fuse,
Thermal Fuse for Fan Motor
Electronic Expansion Valve
R410A M Series
Operation Manual, Installation Manual,
Drain Hose, Clamp Metal, Insulation
for Fitting, Sealing Pads, Clamps,
Screws.
3D038814
SiBE39-402A
FXMQ125MVE
12,500
49,600
14.5
14.0
13,800
54,600
16.0
Galvanized Steel Plate
390×1,110×690
3×16×2.0
0.319
2D11/2D3AF1VE
Sirocco Fan
430×1
36/29
1,271/1,024
191/245-152/172 H4
Direct Drive
Microprocessor Thermostat for
Cooling and Heating
Glass Fiber
H5
φ9.5 (Flare Connection)
φ15.9 (Flare Connection)
VP25
)
(
External Dia. 32
Internal Dia. 25
65
45/42
Fuse,
Thermal Fuse for Fan Motor
Electronic Expansion Valve
R410A M Series
Operation Manual, Installation Manual,
Drain Hose, Clamp Metal, Insulation
for Fitting, Sealing Pads, Clamps,
Screws.
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Specifications
)