SiBE39-402A
Malfunction
Operation
code
Outdoor
LA
Unit
LC
P1
P4
PJ
System
U0
U1
U2
U3
U4
U5
U5
U7
U8
U9
UA
UC
UE
UF
UH
Central-
UE
ized
Control
M1
8 or 7
and
M8
8 or 7
Schedule
Timer
MA
8 or 7
MC
8 or 7
Heat
64
Reclaim
65
Ventila-
68
tion
6A
6A
6F
6H
94
The system operates for malfunction codes indicated in black squares, however, be sure to check and repair.
Troubleshooting
Inspection
Unit No.
lamp
display
9
9
9
9
9
9
9
9
9
9
8
7
9
9
9
9
9
9
9
9
9
9
7
8
9
9
9
9
9
9
9
9
8
8
9
9
9
9
9
9
9
9
9
9
9
9
8
7
8
7
8
7
8
7
9
9
8
7
8
7
9
9
Malfunction contents
Malfunction of power unit
9
Malfunction of transmission between inverter and
9
control PC board
Inverter over-ripple protection
9
Malfunction of inverter radiating fin temperature rise
9
sensor
Faulty combination inverter and fan driver,
9
Malfunction of capacity setting
Low pressure drop due to refrigerant shortage or
9
electronic expansion valve failure
Reverse phase / open phase
9
Power supply insufficient or instantaneous failure
9
Check operation is not conducted.
9
Malfunction of transmission between indoor and
9
outdoor units
Malfunction of transmission between remote
9
controller and indoor unit
Failure of remote controller PC board or setting
7
during control by remote controller
Malfunction of transmission between outdoor units
9
Malfunction of transmission between master and
7
slave remote controllers (malfunction of slave remote
controller)
Malfunction of transmission between indoor unit and
9
outdoor unit in the same system
Excessive number of indoor units etc.
9
Address duplication of central remote controller
8
Malfunction of transmission between central remote
9
controller and indoor unit
Refrigerant system not set, incompatible wiring /
9
piping
Malfunction of system, refrigerant system address
9
undefined
Malfunction of transmission between centralized
9
remote controller and indoor unit
PC board defect
9
Malfunction of transmission between optional
9
controllers for centralized control
Improper combination of optional controllers for
9
centralized control
Address duplication, improper setting
9
Indoor unit's air thermistor error
9
Outside air thermistor error
9
Malfunction of HVU
9
Damper system alarm
9
Damper system + thermistor error
9
Malfunction of simple remote controller
9
Malfunction of door switch or connector
9
Internal transmission error
9
List of Malfunction Code
9: Blink 8: ON 7: OFF
Page
Referred
146
148
149
150
151
153
154
156
157
158
160
161
162
164
165
166
167
168
169
171
107