Daikin R-410A Service Manual page 23

Vrv ii-sr-410a heat pump 50hz
Hide thumbs Also See for R-410A:
Table of Contents

Advertisement

SiBE39-402A
Ceiling Mounted Duct Type
Model
H1 Cooling Capacity (19.5°CWB)
H2 Cooling Capacity (19.0°CWB)
H3 Heating Capacity
Casing
Dimensions: (H×W×D)
Rows×Stages×Fin Pitch
Coil (Cross
Fin Coil)
Face Area
Model
Type
Motor Output × Number
of Units
Fan
Air Flow Rate (H/L)
External Static Pressure
Drive
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Liquid Pipes
Gas Pipes
Piping
Connections
Drain Pipe
Machine Weight
H7 Sound Level (H/L)
Safety Devices
Refrigerant Control
Connectable outdoor unit
Standard Accessories
Drawing No.
Notes:
H1 Indoor temp. : 27°CDB, 19.5°CWB / outdoor temp.: 35°CDB / Equivalent piping length: 7.5m,
H2 Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp.: 35°CDB / Equivalent piping length: 7.5m,
H3 Indoor temp. : 20°CDB / outdoor temp.: 7°CDB, 6°CWB / Equivalent piping length; 7.5m,
H4 Static external pressure is changeable to change over the connectors inside electrical box, this pressure
H5 Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its
6 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
H7 Anechoic chamber conversion value, measured at a point 1.5m downward from the unit center. These
Specifications
FXMQ40MVE
kcal/h
4,000
Btu/h
15,900
kW
4.7
kW
4.5
kcal/h
4,300
Btu/h
17,000
kW
5.0
Galvanized Steel Plate
mm
390×720×690
mm
3×16×2.0
0.181
D11/2D3AB1VE
Sirocco Fan
W
100×1
m³/min
14/11.5
cfm
494/406
157/157-118/108 H4
Pa
Direct Drive
Microprocessor Thermostat for
Cooling and Heating
Glass Fiber
H5
φ6.4 (Flare Connection)
mm
φ12.7 (Flare Connection)
mm
VP25
mm
(
External Dia. 32
Internal Dia. 25
kg
44
dBA
39/35
Fuse,
Thermal Fuse for Fan Motor
Electronic Expansion Valve
R410A M Series
Operation Manual, Installation Manual,
Drain Hose, Clamp Metal, Insulation
for Fitting, Sealing Pads, Clamps,
Screws.
level difference: 0m.
level difference: 0m.
level difference; 0m. (Heat pump only)
means "High static pressure-Standard".
colorimetric method (gravity method) 50% or more.
values are normally somewhat higher during actual operation as a result of installation conditions.
FXMQ50MVE
5,000
19,900
5.8
5.6
5,400
21,500
6.3
Galvanized Steel Plate
390×720×690
3×16×2.0
0.181
D11/2D3AB1VE
Sirocco Fan
100×1
14/11.5
494/406
157/157-118/108 H4
Direct Drive
Microprocessor Thermostat for
Cooling and Heating
Glass Fiber
H5
φ6.4 (Flare Connection)
φ12.7 (Flare Connection)
VP25
)
(
External Dia. 32
Internal Dia. 25
44
39/35
Fuse,
Thermal Fuse for Fan Motor
Electronic Expansion Valve
R410A M Series
Operation Manual, Installation Manual,
Drain Hose, Clamp Metal, Insulation
for Fitting, Sealing Pads, Clamps,
Screws.
3D038814
Specifications
FXMQ63MVE
6,300
25,000
7.3
7.1
6,900
27,300
8.0
Galvanized Steel Plate
390×720×690
3×16×2.0
0.181
D11/2D3AB1VE
Sirocco Fan
100×1
14/11.5
494/406
157/157-118/108 H4
Direct Drive
Microprocessor Thermostat for
Cooling and Heating
Glass Fiber
H5
φ9.5 (Flare Connection)
φ15.9 (Flare Connection)
VP25
)
(
External Dia. 32
Internal Dia. 25
44
39/35
Fuse,
Thermal Fuse for Fan Motor
Electronic Expansion Valve
R410A M Series
Operation Manual, Installation Manual,
Drain Hose, Clamp Metal, Insulation
for Fitting, Sealing Pads, Clamps,
Screws.
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
)
13