Installation; How To Choose An Air Conditioner; Indoor Unit; Outdoor Unit - Hisense AS-09UR4SVNVG1 Service Manual

Split type
Table of Contents

Advertisement

3
.
I
N
S
T
A
L
L
A
T
I
O
3
.
I
N
S
T
A
L
L
A
T
I
O
1、How to choose an air conditioner:
a. Choice for reference: 150-170W/㎡ for average rooms;
b. Choice for reference: 160-200W/㎡ for small size offices;
c. Choice for reference: 220-350W/㎡ for restaurants;
d. Choice for reference: 200-300W/㎡ for entertaining venues;
e. Choice for reference: 220-280W/㎡ for the top floor.
Note:1W = 3.412btu.
2、Indoor Unit:
For indoor unit installation, the distance between its top and the ceiling shall
not be less than 10 cm -20 cm, and the distance from the ground should be
between 2m to 2.6m. Also the wallboard must be smooth and straight, with its
supporting force of not less than 60 kg.
The location for installing the indoor unit shall be far away from heat source,
the space between it and the door or window should exceed 0.6m
3、Outdoor Unit:
The air conditioner outdoor unit should not occupy public sidewalks, the
distance between the mounting bracket installed along the road (on condition that
the mounting bracket does not affect the public access, it can be installed
horizontally) and the ground must exceed 2.5m. Also we shall remember that: a.
the air flow must run freely. b. we should protect famous ancient buildings during
installation. c. the installation does not affect the traffic.
The distance between air outlet of outdoor unit and the opposite object should
be more than 1 meter, otherwise the machine would stop running because of
overload by heat yield failure.
If the outdoor unit was opposite the resident's door or window, you should
install the machine as far as possible away from the adjacent doors windows and
plants, and the distance shall not be less than the following values: for the rated
cooling capacity not more than 4.5KW, the distance should be 3m.; for the rated
cooling capacity more than 4.5KW, the distance should be 4m.
It should remember to avoid installing at places where the natural
environment is harsh, such as heavy fumes and wind, direct sunlight or
high-temperature and heat, together with the place where children easily reach.
4. The Unit:
When installing the air conditioner, the outdoor unit should be below the
indoor unit so as to facilitate circle of refrigerant and refrigeration oil .(1)The
height difference between wall mounted indoor unit and the outdoor unit is
generally not more than 5 meters. (2)The connection pipe can't exceed 5 meters,
and the longest is 15 meters. When the length exceeds 5 meters, 20g fluoride is
required to be added for each exceeding 1m.
N
N

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

As-12ur4svgvgAs-18ur4stvvgAs-12ur4svnvg1As-24ur4sqjvg

Table of Contents