forced cooling with the indoor fan speed being set at high speeds, the
flaps sweeping and the air conditioner's operation is irrelevant with room
temperatures.
6-3-1-3 If a remote signal has been received during the emergency run,
the machine will operate upon the command of such a remote signal.

6-3-2 Operator-machine communication

6-3-2-1 The air conditioner has a thermal sensor to detect room
temperatures. Some remote controller is equipped with a thermal sensor
(Such
remote
communication. For details, refer to the section for the remote
controller). In addition, there is a thermal sensor at the indoor air inlet.
In the case where the remote controller is equipped with a thermal
sensor, the default setting for room temperatures is subject to the
detection by the remote controller. The remote controller detects the
room temperature once every 20 seconds, and automatically transmits a
signal at an interval of 3 minutes or when a change in the room
temperature is detected. If the indoor control unit has not received a
remote signal for more than 10 minutes, the control function will be
automatically switched over to the thermal sensor on the indoor unit.
6-3-2-2 Neither the turning on nor turning off operation will cancel the
operator-machine communication function.
6-3-2-3
In
default,
operator-machine communication function.

6-3-3 Timer function

6-3-3-1 Timer on: When set to start in a time by the remote controller,
the air conditioner starts in the timer on condition. When the set time is
up, the air conditioner will turn on and operates in the preset conditions
after receiving a signal from the remote controller. If the air conditioner
O
D
E
O
D
E
controller
has
the
air
the
function
conditioner
is
of
man-machine
set
to
start
the