6-3-9 Dehumidifying mode

The dehumidifying mode is illustrated as follows:
Indoor Ambient Temperature
Tset
0
16
C
Dehumidifying area I: Operation at the frequency in the range (30–80 Hz)
according to Δt (T
Dehumidifying area II: The compressor stops for 5 minutes and
operators for 5 minutes at the lowest frequency.
Dehumidifying area III: The compressor stops.

6-3-10 Air Blowing mode

The outdoor unit does not work while the indoor fan runs with the fan
speed selectable at the auto, low, medium and high speeds.
O
D
E
O
D
E
I
-T
).
indoor ambient
set
Δt(℃)
0
0.5
1
1.5
≥2
Efficient
II
f(Hz)
30
30
40
50
60
80
III
Time