Operating Instructions and Installation
3-1-2 Name & Function of Key in remote controller
1. AUTO CHANGEOVER FUNCTION :
*To operate in the "Auto change over" mode,
set the MODE on "AUTO".
*According to the outdoor and indoor tem-
peratures while starting the operation, one of
the modes from the cooling, dehumidifying
and heating is selected automatically to
operate.
*The operation mode shall be set again if the
other condition different from that of the
operating conditions(cooling, heating, dehu-
midifying mode) is kept for 60 minutes dur-
ing the change-over operation.
1) Mode selection for operation start
Outdoor
Indoor
temperature
temperature
31˚C over
29˚C over 31˚C less
21˚C over
27˚C over 29˚C less
25˚C over 27˚C less
21˚C over
25˚C less
18˚C over
23˚C over
21˚C less
18˚C less
27˚C over
18˚C over
23˚C less
21˚C less
18˚C less
27˚C less
3-2
Operation
Wind
Set temperature
type
volume
28˚C
27˚C
Cooling
Automatic
26˚C
25˚C
to be set automati-
cally by controller
Dehumid-
according to the
fying
indoor tempera-
ture at the opera-
tion start.
to be set automati-
cally by controller
according to the
indoor tempera-
Heating
ture at the opera-
tion start.
23˚C
21˚C
2) Mode selection during the operation
Outdoor
Indoor
Operation
temperature
temperature
31˚C over
29˚C over 31˚C less
21˚C over
27˚C over 29˚C less
25˚C over 27˚C less
21˚C over
25˚C less
Dehumid-
All area
18˚C over
21˚C less
18˚C less
27˚C over
21˚C over 23˚C less
18˚C less
21˚C less
2. COOL MODE : The unit operates accord-
ing to the difference between the setting
and room temperature.(setting Temp.:
18°C~30°C)
3. HEAT MODE : The unit operates accord-
ing to the difference between the setting
and room temperature.(setting Temp.:
16°C~30°C)
*Prevention against cold wind : For about
3~5 minutes after initial operation (thermo
control or "de-ice"), the indoor fan will
either not operate or operate very slowly,
then switch to the selected fan speed. This
period is to allow the indoor unit's heat-
exchanger to prewarm until emitting
warm air.
Wind
Set temperature
type
volume
28˚C
27˚C
Cooling
Automatic
26˚C
25˚C
to be set automati-
cally by controller
according to the
fying
indoor tempera-
ture at the opera-
tion start.
23˚C
Heating
21˚C
Samsung Electronics