Remote controller operation
method as per the step
4th step
Method)
After completion of 3rd step,
and if the MODE KEY is
pressed once,
! 1~3 steps are saved
internally
@ If the first number at the
time is "1", it is correct
and so go to 5th step
If pressing mode key and
the first digit becomes 0, the
screen of 1~3 steps can be
seen.
5th step
Method)
Pressing the marked key to
input the option number.
example) 142285
Result)
If it displays as shown in the
right
go to the 6th step
6th step
Method)
When pressing the
operation ON/OFF key with
the direction of remote
controller for set, the sound
"Ding, or Diriring is heard
and then the input of option
is completed.
Refer to the right side if
the error appears.
Samsung Electronics
Applicable key
ERROR MODE
1. When the lamps of (STANDARD(
NATURE(
), TIMER(
) is flickering
failute of option input
After removing the set power cord and insert
it again, pressing the operation on/off key to
retry and if the condition is same, EPROM is
deffcective or misinsertted. So replace the
PCB.
Display status
2. When all lamps of indoor unit
),
(
sound of Dididiring,
The current option input is different from
that of already input one: Check the option
number correctly and if it is correct, press the
key once more to input the option. (check
correctly)
If the option is not input at the time and
all lamps are continuously flickering ; since it
is the case that the option number is out of
the input range, check the option number
again and do again the steps from 1 - 6steps
Troubleshooting
) are flickering with the
5-11