4-2 Outdoor Unit
Take care of the electrical shock by contact on the charging parts before the discharge
after power off. (If takes approximately 2 minutes to discharge.)
No
Parts
1
Common Work
&
Ass'y-control Out
4-3
Procedure
1) Loosen the fixing screw and separate the
Cover-Valve.
2) Separate the Cable-Connector Wire from the
Terminal-Block.
3) Loosen five fixing screws and separate the
Cabi-Upper.
4) Loosen five fixing screws from the
Ass'y-Control Out.
5) Separate the Terminal-Housing from the
Ass'y-Control Out.
6) Separate the Ass'y-Control Out from the
outdoor unit.
7) Loosen seven fixing screws and separate the
Cabi-Side.
Remark