Samsung SH12VCD Service Manual page 16

Room air conditioner
Hide thumbs Also See for SH12VCD:
Table of Contents

Advertisement

No
Parts
2
Ass'y Tray Drain.
3
Electrical Parts
(Main PCB)
4
Heat Exchanger
5
Fan Motor and
Cross Fan
Samsung Electronics
Procedure
1) Do "1"above
2) Take all the connector of PCB upper side
out.
(Inclusion Power cord)
3) Separate the outdoor unit connection wire
from the terminal block.
4) If pulling the Main PCB up. it will be taken
out.
1) Do "1", "2" above
Separate the drain hose from the extension
drain hose.
2) Pull tray drain out from the back body.
1) Do "1" and "2", "3" above
2) Loosen two fixing earth screws of right side.
3) Separate the connection pipe.
4) Separate the holder pipe at the rearside.
5) Loosen the three fixing screws of right and
left side.
6) Lifting the heat exchanger up a little to push
the up side for separation from the indoor
unit.
1) Do "1", "2", "3", "4" above.
2) Loosen the fixing two screws and separate
the motor holder.
3) Loosen the fixing screw of fan motor.
(By use of M3 wrench)
4) Separate the fan motor from the fan.
5) Separate the fan from the left holder bear-
ing.
Disassembly and Reassembly
Remark
4-2