Samsung SH12VCD Service Manual page 21

Room air conditioner
Hide thumbs Also See for SH12VCD:
Table of Contents

Advertisement

5-2 The first determination method of troubled part
5-2-1 Error mode display of indoor unit
POWER indicator
NATURE indicator
STANDARD indicator
LAMP of Display Monitor
TIMER
STD
NATURE
X
X
X
X
X
X
X
X
X
X
X
X
5-2
POWER
SAVING
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
TIMER indicator
SILENCE indicator
SAVING indicator
SILENCE
X
Indoor unit room temperature sensor error(open or short)
Indoor unit heat exchanger temperature sensor error
X
(open or short)
X
Indoor fan motor mal function
EEPROM error
Option error
Outdoor unit temperature sensor error(open or short)
- outdoor temp-sensor
- deice temp-sensor
X
- OLP temp- sensor
- discharge temp-sensor
- heatsink temp-sensor
Abnormal communication (Indoor - Outdoor unit)
X
X
\Abnormal increase of operation current
X
Abnormal increase of discharge and OLP temperature
X
Over current of IPM circuit
X
Trouble of the PTC circuit of the outdoor
Trouble of AC current sensor (open/short) and Leakage of
X
refrigerant(R-22)
Remote Control
Sensor
On/Off & 5 Way
Selection button
Description
: LAMP ON
: LAMP FLICKERING
: LAMP OFF
X
Samsung Electronics

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sh09vcdSh12vcdxSh09vcdx

Table of Contents