Services
Least Cost Routing/Destination Restriction

506 Verified Account Codes

Prerequisite Program:
This program adds or deletes entries in the DR Table associated with the DRL entered in
21.
F
IELD
Account Code
01 Verified Flag
02 DRL
03 FRL
04 Network COS
571 Exception Numbers for Forced Account Codes
Prerequisite Program:
Up to four telephone numbers can be programmed as exceptions to the forced and /or verified account code
entries (including 911). These special codes enable numbers to bypass the verification process and proceed
unhindered.
F
IELD
01 Exception Number 1
02 Exception Number 2
03 Exception Number 3
04 Exception Number 4
9-24
570
on page 9-23
D
ESCRIPTION
Enter a valid accounting code that the user will be expected to dial. Digits 0~9
can be used.
Note
The Account Code is set to the same digit length as the Verified Digit
Length in Program 570 above.
Possible values: Up to 15 ASCII characters (default = no value)
The Account Code Flag determines whether the number entered is to be used
as a verified account code or not. Some applications may allow users to dial an
accounting code which changes the restriction level for the call allowing it to be
placed.
Possible values: Set or No Set (default)
Note
To delete a Verified Account Code set this field to No
The DRL assigned to an accounting code allows users to override their
stations assigned DRL enabling a call to be placed.
Possible values: 0~16 (default = 0)
The FRL assigned to an accounting code enables users to override the station
assigned FRL.
Possible values: 0~16 (default = 0)
Assign the Network COS to be used by this accounting code.
Possible values: 1~32 (default = 1)
506
on page 9-24
D
ESCRIPTION
Enter a Forced Account Code Exception.
Possible values: Up to 4 digits
Exception 1 default = 911
Exception 2~4 default = no value
Note
One of the assigned exception numbers should be 911. Exception
Numbers for Forced Account Code fields cannot be duplicated.