N-Ca55-500Tr Service Avv (Air Valve Vacuum) Testing - Daewoo G420E Service Manual

Tier lp engine lift trucks with tier lp engine tier lp engine
Table of Contents

Advertisement

N-CA55-500TR Service AVV
(Air Valve Vacuum) Testing
AVV Test Hardware
1. Mixer AVV test fitting ¼" NPT X ¼" hose barb.
2. Union Tee ¼" NPT with three ¼" NPT X ¼" hose
barb.
3. Vacuum hose.
4. 0-20 in W.C. Magnehelic Gauge (inches of water
column).
AVV Test
1. Install the Union Tee fitting between the FTV and
the AVV fitting.
2. Connect the vacuum hose from the Union Tee
fitting to the Magnahelic gauge (Figure T1). You
should now have the gauge inline between the
FTV and the mixer to throttle adapter.
3. With the engine running at idle (700 RPM) the
AVV should be between 5" and 10" water column.
Gauge
Fitting
Figure T1
Tier
G420E/G424E
AVV Fitting
LP Engine
NOTE
If the measured water column is
excessively high, check for a sticking or
binding piston diaphragm assembly
inside the mixer. (See Chapter 8 for
removal, installation and disassembly of
the N-CA55-500TR mixer).
WARNING
DO NOT spray carburetor cleaner or
solvent into the mixer while installed on
the engine. These chemicals may damage
the oxygen sensor and cause pre-mature
failure of the catalytic muffler.