Testing Fuel Lock-Off Operation; Pressure Regulator/Converter Testing And Nspection; Fuel Trim Valve Inspection (Ftv); Inspect Air/Fuel Valve Mixer Assembly - Daewoo G420E Service Manual

Tier lp engine lift trucks with tier lp engine tier lp engine
Table of Contents

Advertisement

Testing Fuel Lock-off
Operation
Start engine.
Locate the electrical connector for the fuel lock
(A).
Disconnect the electrical connector.
The engine should run out of fuel and stop within
a short period of time.
Turn the ignition key switch off and re-connect
the fuel lock-off connector.
A
(A) LP fuel lock-off (B) LP regulator/converter
(C) Fuel Trim Valve
NOTE
The length of time the engine runs on
trapped fuel vapor increases with any
increase in distance between the fuel
lock-off and the pressure
regulator/converter.
Pressure
Regulator/Converter Testing
and Inspection
Visually inspect the pressure regulator/converter
(B) housing for coolant leaks. Refer to the
pressure regulator/converter section of the
service manual if maintenance is required.
NOTE
For pressure testing and internal
inspection of the pressure
regulator/converter, refer to the pressure
regulator/converter section of the service
manual.
Tier
G420E/G424E
C
B
LP Engine
Fuel Trim Valve Inspection
(FTV)
Visually inspect the Fuel trim valve (C) for
abrasions or cracking. Replace as necessary.
To ensure the valve is not leaking a blow-by test
can be performed.
1. With the engine off, disconnect the electrical
connector to the FTV.
2. Disconnect the vacuum line from the FTV to the
pressure regulator/converter, at the converter's
tee connection.
3. Lightly blow through the vacuum line connected to
the FTV. Air should not pass through the FTV
when de-energized. If air leaks past the FTV when
de-energized replace the FTV.
Inspect Air/Fuel Valve Mixer
Assembly
Refer to the LP mixer (G) section of the service
manual for procedures.