Fault stimulus
Server path failure
Storage path failure

NetWare

Fault stimulus
Server failure (host power-cycled)
Switch failure (SAN switch disabled)
Controller failure
Controller restart
Server path failure
Storage path failure
76
Single path implementation
Failure effect
If the LUN is not shared, I/O is suspended or process is terminated across this HBA
until path is restored.
If running OpenVMS 7.3-1 and the LUN is shared, another cluster node having
direct access will take over serving the device, resulting in no loss of service.
In either case, no data is lost or corrupted.
The operating system will report the volume in a Mount Verify state until the
MVTIMEOUT limit is exceeded, when it then marks the volume as Mount Verify
Timeout.
I/O is suspended or process is terminated across this HBA until path is restored. No
data is lost or corrupted.
The operating system will report the volume in a Mount Verify state until the
MVTIMEOUT limit is exceeded, when it then marks the volume as Mount Verify
Timeout.
Failure effect
OS reboots. When mounting volumes, volume repair or NSS rebuild
executes to cleanup volumes. Data loss, data that finished writing
survived.
I/O to device stops with I/O errors indicated on server console.
Applications using lost connection halts. Server restart recommended
but may not be necessary. Volume repair or NSS rebuild runs when
volumes are mounted.
I/O to device stops with I/O errors indicated on server console.
Applications using lost connection halts. Server restart recommended
but may not be necessary. Volume repair or NSS rebuild runs when
volumes are mounted.
I/O to device stops with I/O errors indicated on server console.
Applications using lost connection halts. Server restart recommended
but may not be necessary. Volume repair or NSS rebuild runs when
volumes are mounted.
I/O to device stops with I/O errors indicated on server console.
Applications using lost connection halts. Server restart recommended
but may not be necessary. Volume repair or NSS rebuild runs when
volumes are mounted.
I/O to device stops with I/O errors indicated on server console.
Applications using lost connection halts. Server restart recommended
but may not be necessary. Volume repair or NSS rebuild runs when
volumes are mounted.