Care Of Your Opener; Maintenance Of Your Opener; Operation Of Your Opener; Specifications - Chamberlain ML750 Installation And Operating Instructions Manual

Sectional & tilt garage door opener
Hide thumbs Also See for ML750:
Table of Contents

Advertisement

OPERATION OF YOUR OPENER

Your opener can be activated by any of the following devices:
• The backlit door control button (if installed). Hold the button
down until door starts to move.
• The outside keyswitch or keyless entry system (if you have
installed either of these accessories).
• The remote control transmitter. Hold the push button down until
the door starts to move.
Opening the door manually:
Door should be fully closed if possible. Weak or broken
springs could allow an open door to fall rapidly. Property
damage or serious personal injury could result.
The door can be opened manually by pulling the release handle
down. To reconnect the door, pull the release handle down and
toward the opener.
Do not use the manual release handle to pull the door open
or closed.
When the opener is activated by remote control or backlit door
control button:
1. If open, the door will close. If closed, the door will open.
2. If closing, the door will stop.
3. If opening, the door will stop (allowing space for entry and exit of
pets and for fresh air).
4. If the door has been stopped in a partially open or closed position,
it will reverse direction.
5. If an obstruction is encountered while closing, the door will
reverse.
6. If an obstruction is encountered while opening, the door will
reverse, then stop.
7. The optional Protector System™ uses an invisible beam which,
when broken by an obstruction, causes a closing door to open
and prevents an open door from closing. It is STRONGLY
RECOMMENDED for homeowners with young children.
Allow a 15 minute cooling period after 5 continuous operations
of the opener.
The opener light will turn on:
1. when opener is initially plugged in;
2. when the power is briefly interrupted;
3. when the opener is activated.
The light turns off automatically after 2-1/2 minutes. Bulb size is
24V/21W maximum.

MAINTENANCE OF YOUR OPENER

Once a Year:
• Apply grease to rail and trolley
• Oil door rollers, bearings and hinges
• DO NOT lubricate the opener itself
• DO NOT APPLY grease to the door tracks
SPECIAL NOTE: Chamberlain strongly recommends that the Protector System

CARE OF YOUR OPENER

When properly installed, your opener will operate with minimal
maintenance. The opener does not require additional lubrication.
Limit and force settings: These settings must be checked and
properly set when opener is installed. Weather conditions may cause
some minor changes in the door operation, requiring some
re-adjustments, particularly during the first year of operation.
Refer to setting the limits and force on page 9. Follow the instructions
carefully and repeat the safety reverse test after any adjustment.
Remote control: The remote control may be secured to a car sun
visor with the clip provided. Additional remotes can be purchased at
any time for use in all vehicles using garage. Refer to accessories.
Any new remotes must be programmed into the opener.
Remote control battery: If transmission range decreases, replace
battery.
To change battery: To replace batteries, use the visor clip or
screwdriver blade to pry open the case. Insert batteries positive side
up. To replace cover, snap shut along both sides. Do not dispose of
the old battery with household waste. Take batteries to a proper
disposal centre.

SPECIFICATIONS

Input Voltage
230-240 VAC, 50Hz
Max. Pull Force ..............600N
Power .............................115W
Standby Power ...............5.5W
Normal Torque ................7Nm
Motor
Type ................................DC gearmotor permanent lubrication
Drive Mechanism
Drive ...............................Belt with two-piece trolley on
steel rail
Length of Travel..............Adjustable to 2.3m
Travel Rate .....................127-178mm per second
Lamp...............................On when door starts, off 2-1/2 minutes
after stop
Door Linkage ..................Adjustable door arm. Pull cord trolley release
Safety
Personal .........................Push button and automatic stop in down
direction. Push button and automatic stop in
up direction
Electronic ........................Automatic force adjustment
Electrical .........................Transformer overload protector and low
voltage push button wiring
Limit Device ....................Optical RPM/Passpoint detector
Limit Adjustment .............Electronic, semi and fully automatic
Start Circuit.....................Low voltage push button circuit
Dimensions
Length (Overall)..............3.2m
Headroom Required .......30mm
Hanging Weight ..............16kg
Receiver
Memory Registers ..........12
Operating Frequency......433.92MHz
TM
be installed on all garage door openers.
18

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents