Display of selected functions
Table II: Unit protection devices
Type of protection
Cold draft
prevention
(active on heating)
Defrost cycle
(active on heating)
Electric heater
protection
(unit with electric heater only)
Freeze-up protection
(active on cooling and dehumidification)
Against frequent
compressor cycling
WARNING:
Models with electric heaters: the unit is fitted with two thermostats - one with automatic reset and one with manual reset. If the manual thermostat also trips the
circuit, investigate and correct the cause. Switch OFF and ON the power supply to the electric heaters in order to reset the thermostat.
During heat pump operation the unit will undergo several defrost cycles to eliminate any ice that may have collected on the outdoor unit in very low ambient
temperatures. During these cycles, the indoor fan is automatically stopped and cannot be switched on until the defrost cycle is completed.
GB - 6
1. Signal transmission symbol
2. Operating mode display
3. Dehumidification only
4. Cooling and dehumidification
5. Automatic
6. Heating
7. Ventilation (fan only)
8. Temperature display
9. Temperature selected
10. Timer operating mode display
11. Combined timer start/stop program
12. Night stop function
13. Stop program
14. Start program
15. Clock display
16. Actual time or programmed start/stop time
17. Air function display
18. Fan speed
19. Air outlet louvre operation
Condition for activation
With fan in AUTOMATIC
indoor fan OFF and
red LED on selected.
Indoor and outdoor fan OFF and
red LED on louvres in a different
position from that selected.
Fan will stop for 30 sec. after
unit is turned OFF (red LED on).
Compressor and outdoor fan OFF
Compressor OFF for about 3 minutes
: