6) Timing Charts
a)
Data receiving timing
PARALLEL DATA
(DATA BITs 1 to 8)
DATA STOROBE
BUSY
ACKNOWLEDGE
On-line → off-line switching timing by ON-LINE SW
b)
ON-LINE SW
BUSY
SELECT
Off-line → on-line switching timing by ON-LINE SW
c)
ON-LINE SW
BUSY
SELECT
ACKNOWLEDGE
d)
INPUT PRIME timing (when set to the effective INPUT PRIME signal)
INPUT. PRIME
BUSY
SELECT
ACKNOWLEDGE
41356801TH Rev.1
0.5 µs min.
0.5 µs min.
0.5 µs max.
0 min.
0.5 µs to 10 µs
100 ms max.
100 ms max.
0.5 µs to 10 µs
50 µs min.
5µs max.
10 µs max.
0.5 µs min.
0.5 µs min.
0 min.
0 min.
0 min.
0 min.
0 min.
0.5 µs to 10 ms