Weber 3000 Owner's Manual page 29

Lp gas barbecue
Hide thumbs Also See for 3000:
Table of Contents

Advertisement

C) To check for leaks, wet fittings with the soap and water
solution, using a spray bottle, brush or rag. If bubbles
form, or if a bubble grows, there is a leak. Apply the
soap and water solution to the following connections:
a) Manifold-to-regulator hose connection (7).
b) Valve-to-outside burner tube gas line connection
(8).
c) Valve-to-inside burner tube gas line connection
(9).
d) Regulator-to-cylinder connection (10).
e) Regulator hose-to-regulator connection (11).
m WARNING: If there is a leak at
connections (7, 8, 9, 10 or 11), turn
off the gas. DO NOT OPERATE THE
BARBECUE. Contact the Customer
Service Representative in your area
using the contact information on our
web site. Log onto www.weber.com
D) When leak checking is complete, turn gas supply off at
the source and rinse connections with water.
NOTE: Since some leak test solutions, including soap and
water, may be slightly corrosive, all connections should be
rinsed with water after checking for leaks.
Now you are ready to use your barbecue.
PREPARING TO USE YOUR BARBECUE
7
.
®
10
8
9
11
29