Troubleshooting

Symptom
Colors in the monitor screen
are abnormal. (During
genlocking)
Synchronization is not
possible.
Video
troubles
SD SDI signal level is not
outputted correctly (RM-
HP250AU only)
Pressing the corresponding
button cannot start the
operation.
<EXT> is displayed on the LCD.
The LCD display keeps on
displaying "NOW INITIALIZING
JUST A MOMENT".
The LCD display keeps on
display "PLEASE CHECK THE
CAMERA".
LCD display shows "---".
White-balance adjustment
cannot be started.
Control
troubles
The white balance adjustment
will not complete.
The tally lamp does not light.
Incorrect operation even when
FAS button is ON.
"E.02" will be displayed on RM-
LP25U
OPERATE button of RM-LP25U
keeps blinking.
Check Points
Is the SC phase adjusted properly?
Are the Tri-level sync signal or BB signals applied to the
GENLOCK INPUT connectors?
Is the VTR playback signal supplied directly without passing
through a TBC?
Is the SETUP LEVEL setting of camera set to the value same as
SETUP LEVEL setting of RM-HP250AU?
Functions that are not available on the camera cannot be
controlled.
Are cables connected properly?
Is the power switch of the camera set to ON?
Are cables connected properly?
Is the power switch of the camera set to ON?
(When power of camera is turned off while RM-HP250 is on,
"PLEASE CHECK THE CAMERA" will be displayed after about 20
seconds if RM-HP250 is operated.
In addition, when turning on RM-HP250 while the power switch of
camera is off, similar display will appear after about 30 seconds. )
The connected camera does not have the assigned function.
Check the camera functions again and assign the proper
functions to the F1 to F4 keys.
Is the W.BAL switch set to A or B?
Is FAS or FAW ON (which is indicated by the lighting of the AUTO
light)?
Are the color temperature filters and lighting conditions appropriate?
Does the object have colors?
Is the tally system of the RM-HP250 compatible with that of the
camera system?
The RM-HP250 has been set to the voltage supply at the factory.
If it is required to use the TALLY input in the contact supply mode,
the setting of the internal circuitry should be changed ; consult the
nearest JVC-authorized service agent.
Is the STUDIO cable of KA-HD250U pulled out or loose?
Are cables connected properly?
Is the power switch of the camera set to ON?
(When power of camera is turned off while RM-HP250/RM-LP25U is
on, similar display will appear after about 10 seconds.)
Are cables connected properly?
Is the power switch of the camera set to ON?
(When turning on RM-HP250/RM-LP25U while the power switch of
camera is off, the OPERATE button will keep blinking.)
General
Action
P. 13
P. 13
P. 26
Check the
camera
functions
again.
P. 8
P. 9
P. 10
P. 8
P. 9
P. 10
P. 25
P. 18
P. 18
P. 14
Connect the
cable properly.
P. 8
P. 9
P. 10
P. 8
P. 9
P. 10
31