Adjustments for Genlock Operation

Genlocking is required for a system, which uses an SEG (special effects generator) as the main
signal source.
REF. : "Example of Connection with 2 Units" on page 9.
NOTE
The following adjustments can be made more accurately when using a vectorscope and waveform monitor.
Be sure to use an underscanned video monitor.
It is not permitted to genlock the system components using a VCR playback signal.
Before phase adjustment, wait a little for the phases of the connected components to stabilize.
FULL AUTO
F1
SHUTTER
1: GENLOCK
2: CABLE
BARS
F2
GAIN
M
BARS button
LCD display
Cursor
4.
1: GENLOCK
2: CABLE
Item
5A.
1A: SD H PHASE
5B.
1B: HD H PHASE
6A.
1A: SD H PHASE
6B.
1B: HD H PHASE
7.
1C: SC COARSE
8.
1C: SC COARSE
9.
1D: SC FINE
10.
1D: SC FINE
11.
STR
CMP
F3
MENU/SHUTTER
GAIN
P
STEP
HIGH
SHUTTER
VARIABLE
MID
PUSH-ON
PUSH-ON
R
F4
MENU
LOW
DOWN
UP
DOWN
UP
Control knob
MENU button
Setting
0
0
Cursor
127
1023
0 °
90 °
0
127
OFF
ALC
0 dB
LUX
Preparations and Main Functions
Preparation
1.
Press the BARS button to output the color bar signal. The
button light should light up.
2.
Output the built-in color bar signal of the SEG from the
program connector on the front panel of the SEG. (Refer
to the INSTRUCTIONS MANUAL of the SEG.)
3.
Observing the monitor screen at the same time, adjust
the H PHASE (horizontal phase) and SC (subcarrier
phase) while using the switch on the SEG to alternately
change between color bars of the internal RM-HP250 that
of the SEG.
Adjusting the H PHASE
4.
Press and hold the MENU button for about 3 seconds until
the LCD display shows the menu display.
5.
Ensure that the cursor ( ) is located on "1: GENLOCK",
then press the control knob to display "1A: SD H PHASE"
or "1B: HD H PHASE".
6.
Press the control knob to move the cursor ( ) to the cur-
rently set value, then turn the control knob to adjust the H
PHASE value (HD: –1024 to 1023, SD: –128 to 127).
After the adjustment, press the control knob to move the
cursor ( ) back to "1: GENLOCK".
NOTE
Screens 5 and 6 differ according to the VIDEO FORMAT
of the camera.
Adjusting SC phase (Only for SD signal)
7.
Turn the control knob to display "1C: SC COARSE".
8.
Press the control knob to move the cursor ( ) to the cur-
rently set value, then turn the control knob to adjust the
SC COARSE value (to 0°, 90°, 180° or 270°).
9.
After the coarse adjustment, press the control knob to
move the cursor ( ) back to "1C: SC COARSE", then
press the control knob to display "1D: SC FINE".
10 .
Press the control knob to move the cursor ( ) to the cur-
rently set value, then turn the control knob to adjust the
SC FINE value (from -128 to 127).
NOTE
SC COARSE and SC FINE are linked.
When the upper or lower limit of SC FINE is exceeded,
the value of SC COARSE changes.
For example, when the value of SC COARSE is 0° and
SC FINE is increased, once SC FINE exceeds 127, SC
COARSE will become 90° and SC FINE will become -
128.
11 .
After the adjustment, press the MENU button to return to
the previous display.
12 .
Press the BARS button to stop the color bar signal output.
13