BW Technologies MicroClip XT Technical Reference Manual page 43

1, 2, 3, and 4-gas detector
Hide thumbs Also See for MicroClip XT:
Table of Contents

Advertisement

GasAlertMicroClip XT
Technical Reference Guide
Alarm
Multi-Gas Alarm
• Sequence alternating low and high alarm
siren and flash
• L and gas bars flash
• Vibrator alarm activates
Sensor Alarm
• During startup sequence
Error [sensor name] displays
• During normal operation
Err displays (must be acknowledged by
press C)
Low Battery Alarm
• Sequence of 10 rapid sirens and alternat-
ing flashes with 7 seconds of silence in
between (continues for 15 minutes)
and L flash, LOW BAT displays,
and the vibrator alarm activates
• After 15 minutes, of the Low Battery
alarm, the Automatic Shutdown Alarm
sequence begins
displays before deactivating
OFF
32
Screen
Over Limit (OL) Alarm
• Fast siren and alternating flash
• L and gas bar flash
• Vibrator alarm activates
• OL displays
Confidence Beep and IntelliFlash
• One beep and flash every second
The detector is shipped with Confidence
Beep disabled and IntelliFlash enabled
Automatic Shutdown Alarm
• Sequence of 10 rapid sirens and alternating
flashes with 1 second of silence in between
(sequence reactivates seven times)
• LOW BAT and L display
• Vibrator alarm activates
• OFF displays before deactivating
Normal Shutdown
• Sequence of two sirens and alternating
flashes
• Vibrator alarm activates
• Countdown initiates
displays
OFF
Alarm