Furnace Start -U P; Operation; Furnace Shut Down - Goodman GAS-FIRED WARM AIR FURNACE User's Information Manual

Gas-fired warm air furnace
Hide thumbs Also See for GAS-FIRED WARM AIR FURNACE:
Table of Contents

Advertisement

T
HERMOSTAT
There are many types and styles of thermostats but the operation is
usually similar. BE SURE TO BECOME FAMILIAR WITH YOUR
THERMOSTAT. The simplest type of thermostat only starts and
stops the furnace to maintain the desired room temperature. The
most widely used types will control both heating and cooling func-
tions and will have a Fan Switch with Auto and ON settings. On Auto,
the circulating air blower will cycle on/off with the furnace but if
switched to ON it will run continuously regardless of whether or not
heating or cooling is being provided.
In addition, there are thermostats which automatically switch from
heating to cooling mode and those with night set back capability.
The night set back, or multiple set back, type allows for a different
temperature at night or during the day when no one is at home.
Programmable thermostats will allow for more control and tailoring
of the heating and cooling functions. The level of this control will
depend on the type of thermostat applied.
Room Temperature
Cool/Heat
Thermostat
Temperature
Control Dials
Cool/Heat
Fan Switch
Switch
F
URNACE
E
LECTRICAL COMPONENTS ARE CONTAINED IN BOTH COMPARTMENTS.
AVOID PERSONAL INJURY, ELECTRICAL SHOCK OR DEATH, DO NOT REMOVE
ANY INTERNAL COMPARTMENT COVERS.
ONCE IF AN ABNORMAL CONDITION IS NOTICED.
Keep both doors in place except for inspection and maintenance. An
interlock switch prevents furnace operation if the blower door is not
in place.
F
S
-U
URNACE
TART
P
1. Close the external manual gas shut-off valve.
2. Turn off the electrical power to the furnace.
3. Set the room thermostat to the lowest possible setting.
4. Remove the burner compartment door.
5. This furnace is equipped with an ignition device which automati-
cally lights the burner. Do not try to light the burner by hand.
6. Move the furnace's gas valve ON/OFF switch to the OFF posi-
tion.
7. Wait five minutes to clear out any gas. Then smell for gas, in-
cluding near the floor as some types of gas are heavier than air.
8. If you smell gas following the five minute waiting period in step 7,
immediately follow the instructions on the cover of this manual.
If you do not smell gas after five minutes, move the furnace's
gas valve ON/OFF switch to the ON position.
9. Replace the burner compartment door.
10. Open the external manual gas shut-off valve.
11. Turn on the electrical power to the furnace.
12. Adjust the thermostat to a setting above room temperature.
13. After the burners are lit, set the thermostat to desired tempera-
ture.
F
UNCTIONS
System
Fan
Action
Switch
Switch
OFF
AUTO
None
System only cools, fan
COOL
AUTO
cycles off and on.
System only cools, fan
COOL
ON
runs all the time.
System only heats, fan
HEAT
AUTO
cycles off and on.
System only heats, fan
HEAT
ON
runs all the time.
No heating or cooling,
OFF
ON
fan runs all the time.
O
PERATION
WARNING
C
ONTACT A QUALIFIED SERVICER AT
Gas Valve
On/Off
Selector
Switch
INLET
White-Rodgers Model 36F22 (Single-Stage)\
OUTLET
White-Rodgers Model 36G22 (Single-Stage)
Outlet (Manifold)
Pressure Tap
(Side of Valve)
Regulator Adjustment
Screw (Under Cap)
White-Rodgers Model 36E54 (Two-Stage)
F
S
D
URNACE
HUT
OWN
To shut down your furnace, follow the steps listed below.
1. Set the thermostat to the lowest setting.
2. Integrated control closes gas valve extinguishing flame.
T
O
3. Induced draft blower is de-energized following a 15 second de-
lay. The circulator blower is de-energized following a 60, 90,
120, or 180 second delay period.
4. Remove the burner compartment door.
5. Move the furnace's gas valve ON/OFF switch to the OFF posi-
tion.
6. Close the external manual gas shut-off valve.
7. Replace the burner compartment door.
Furnace lockout is characterized by a non-functioning furnace
(circulator blower may be running continuously) providing a one
flash diagnostic LED code. Lockout results when a furnace control
detects abnormal conditions. If the furnace is in "lockout", it may be
reset by any of the following methods:
1. One hour automatic reset. Control will automatically reset itself
and attempt to resume normal operations following a one hour
lockout period.
2. Power interruption. Interrupt 115 volt power to the furnace for
between 0 and 20 seconds.
3. Thermostat cycle. Interrupt thermostat signal to the furnace for
between 0 and 20 seconds.
If the condition which originally caused the lockout still exists, the
control will return to lockout. If your furnace frequently locks out, a
problem exists which must be corrected.
servicer.
Maintenance is to be performed by a qualified service technician
only. User maintenance is to be restricted to frequent air filter
changes and to ensure the warnings and notices found elsewhere
4
Gas Valve
On/Off
Selector
Switch
Gas Valve
Low Manifold
ON/OFF Switch
Regulator Adjustment
Screw (Under Cap)
Inlet Pressure Tap
(Side of Valve)
High Manifold
L
R
OCKOUT
ESET
R
M
OUTINE
AINTENANCE
OUTLET
INLET
Manometer
Hose
Contact a qualified