Goodman GAS-FIRED WARM AIR FURNACE User's Information Manual

Gas-fired warm air furnace
Hide thumbs Also See for GAS-FIRED WARM AIR FURNACE:

Advertisement

I
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
S
HOULD OVERHEATING OCCUR, OR THE GAS SUPPLY FAIL TO SHUT OFF,
SHUT OFF THE MANUAL GAS VALVE TO THE FURNACE BEFORE SHUTTING OFF
THE ELECTRICAL SUPPLY.
Part No. HI-115
Printed in USA
GAS-FIRED WARM AIR FURNACE
U
'
SER
S
F THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION
D
O NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE.
WHAT TO DO IF YOU SMELL GAS
D
O NOT TRY TO LIGHT ANY APPLIANCE.
D
O NOT TOUCH ANY ELECTRICAL SWITCH; DO NOT USE ANY PHONE IN YOUR BUILDING.
I
MMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR'S PHONE.
SUPPLIER'S INSTRUCTIONS.
I
F YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE DEPARTMENT.
I
NSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY
OR THE GAS SUPPLIER.
Installer - Affix this manual, Installation Guide, and Warranty adjacent to the
appliance.
Owner - Read and keep all product literature in a safe place for future
reference.
WARNING
P
RODUCT CONTAINS FIBERGLASS WOOL.
THIS PRODUCT DURING INSTALLATION, MAINTENANCE, OR REPAIR WILL
EXPOSE YOU TO FIBERGLASS WOOL.
F
CANCER. (
IBERGLASS WOOL IS KNOWN TO THE
F
CAUSE CANCER.)
AND EYE IRRITATION.
INFORMATION, CONSULT MATERIAL SAFETY DATA SHEETS AVAILABLE FROM
ADDRESS SHOWN BELOW.
RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.
Due to policy of continual product
improvement, the right is reserved to
change specifications and design
I
M
NFORMATION
WARNING
:
T
O AVOID PROPERTY DAMAGE, PERSONAL INJURY OR DEATH, DO NOT USE
THIS FURNACE IF ANY PART OF THE FURNACE HAS BEEN UNDER WATER.
I
MMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE
FURNACE AND TO REPLACE ANY PART OF THE CONTROL SYSTEM AND ANY
GAS CONTROL HAVING BEEN UNDER WATER.
WARNING
D
ISTURBING THE INSULATION IN
B
REATHING THIS MAY CAUSE LUNG
S
IBERGLASS WOOL MAY ALSO CAUSE RESPIRATORY, SKIN,
T
O REDUCE EXPOSURE OR FOR FURTHER
without notice.
ANUAL
F
OLLOW THE GAS
WARNING
C
TATE OF
ALIFORNIA TO
2004 Goodman Company, L.P.
Effective: June 2004

Advertisement

Table of Contents
loading

Summary of Contents for Goodman GAS-FIRED WARM AIR FURNACE

  • Page 1 GAS-FIRED WARM AIR FURNACE ’ NFORMATION ANUAL WARNING F THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. – O NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
  • Page 2 AFETY 3. Do not use the furnace closet as storage for brooms, mops, brushes and oily rags or cloths. The area must be kept clear, IGNAL ORDS clean and free of lint. Furnace must be kept free and clear of Dear Homeowner, please recognize the following safety informa- exposed or loose insulation materials in the area of installation.
  • Page 3: Combustion Air

    If fuel-burning appliances are starved for air, the flue gases which NDOOR UMIDITY these appliances produce as they operate may not vent outdoors Relative humidity is the amount of water vapor in the air relative to properly, but remain in the home instead. These flue gases may the amount the air can hold at the same temperature.
  • Page 4: Furnace Start -U P

    Gas Valve HERMOSTAT UNCTIONS On/Off Selector There are many types and styles of thermostats but the operation is Switch usually similar. BE SURE TO BECOME FAMILIAR WITH YOUR INLET OUTLET THERMOSTAT. The simplest type of thermostat only starts and stops the furnace to maintain the desired room temperature. The White-Rodgers Model 36F22 (Single-Stage)\ most widely used types will control both heating and cooling func- tions and will have a Fan Switch with Auto and ON settings.
  • Page 5 in this manual be followed. We recommend that at a minimum another qualified servicer. system maintenance be performed by a qualified service technician Filters must be inspected, cleaned or changed every two months or prior to the beginning of each heating season, and if equipped with as required.
  • Page 6 AFETY ABELS NOTE: If safety labels are missing or illegible, contact the installing dealer or our Customer Service Department for ordering information.
  • Page 7: Safety Labels

    AFETY ABELS CARBON MONOXIDE POISONING HAZARD Special Warning for Installation of Furnace or Air Handling Units in Enclosed Areas such as Garages, Utility Rooms or Parking Areas Carbon monoxide producing devices (such as an automobile, space heater, gas water heater, etc.) should not be operated in enclosed areas such as unventilated garages, utility rooms or parking areas because of the danger of carbon monoxide (CO) poisoning resulting from the exhaust emissions.
  • Page 8: Troubleshooting

    MODEL NUMBER: _ _ _ _ _ _ _ _ _ _ _ MANUFACTURING NUMBER: P _ _ _ _ _ _ _F SERIAL NUMBER: _ _ _ _ _ _ _ _ _ _  2004 Goodman Company, L.P. Effective: June 2004...

Table of Contents