Thermos 4656110 Assembly Manual page 25

Table of Contents

Advertisement

• Do not use grill until leak checked.
• If leak is detected at any time, STOP and call the Fire Department.
• If you cannot stop a gas leak, immediately close LP tank valve and call
LP gas supplier or your fire department!
Leak Testing Valves, Hoses and Regulator
1. Turn grill control knob to OFF.
2. Be sure connector is tightly connected to LP tank.
3. Completely open LP tank valve by turning hand wheel counter clockwise. If you hear
a rushing sound, turn gas off immediately. There is a major leak at the connection.
Correct before proceeding.
4. Brush soapy solution onto following connections:
Valve connection
5. "If growing" bubbles appear, there is a leak. Close LP tank valve immediately and
retighten connections. If leaks cannot be stopped "do not try to repair" call for
replacement parts. Order new parts by giving the serial, model number and name of
items needed to the Grill Service Center at !1-800-241-7548.
6. Always close LP tank valve after performing leak test by turning hand wheel
clockwise.
WARNING
WARNING
WARNING
WARNING
WARNING
.
Regulator
connection.